Instructions

20
MultiWet-Master Compact
1
3
7
6
5
8
9
16
17
18
19
20
11
10
12
13
14
15
MultiWet-Master Compact
4
2
4
EN
1
2
3
4
5
6
7
8
9
Measuring probes,
resistance measuring principle
Sensor pads
capacitive measuring principle
Pop-out sensor for measuring
ambient temperature and
humidity
Battery compartment
LC display
Wet/dry LED indicator
Measuring mode selection
(Resistance measuring principle,
Capacitive measuring principle)
Material selection
ON/OFF
10
11
12
13
14
15
16
17
18
19
20
Bluetooth active
Ambient temperature in °C/°F
Relative humidity in %
Dew point temperature in °C/°F
Material indicator for wood
Resistance measuring principle: A, B, C
Capacitive measuring principle:
softwood (S), hardwood (H)
Capacitive measuring principle
Battery charge
Material indicator for building materials
Resistance measuring principle: 1…8
Index mode / Index Zoom mode
Measured value in %
of relative material moisture
Resistance measuring principle
Room climate - measured values
The measuring device features a fold-out
sensor that measures the ambient temperature
(A-Temp, 11) and relative humidity (RH, 12)
while also calculating the dew point tempera-
ture (D-Temp, 13). By folding out the sensor,
the improved through-ow of air speeds up
the measurement procedure.
When changing location and/or where there are large differences in
the room climate, it is important to give the measuring device time
to adapt until the measured values in the display have stabilized.
!