The device starts automatically in Index mode and does not always need to
be calibrated to zero in mid-air to compensate environmental inuences. The
spherical measuring head must not be in contact with the user's hands or
other objects during calibration. For zero calibration, hold down the ‘FIND’
button and hold the device in a free space. Continue to hold the ‘FIND’ button
down after the beep and position the spherical measuring head perpendicular
to the item to be measured. Once the measured value appears in the display,
release the ‘FIND’ button. The measured value is retained automatically.
Hold
down
Measuring process
Index mode is used to rapidly locate moisture with
comparative measurements, without a direct
output of material moisture in %. The output value
(0 through 199.9) is an indexed value that increases
as material moisture becomes greater. Measurements
made in index mode are independent of material
type and particularly useful with materials for which no characteristics are
stored. When comparative measurements reveal strongly deviating values,
the course of moisture in the material can be localized quickly.