Technical data
ThermoCamera HighSense ThermoCamera HighSense Pro
Sensor type uncooled microbolometer
Infrared temperature resolution
160 x 120 pixels 384 x 288 pixels
Resolution display 640 x 480 pixels
Field of view (FOV) 20.7° x 15.6° 41.5° x 31.1°
Spatial resolution (IFOV) 2,26 mrad 1,89 mrad
Focus adjustable
Shutter Period Auto, 1 min, 3 min, 5 min, 10 min, 15 min, 30 min, Off
Thermal sensitivity (NETD) < 50 mK @30°C
Measurement range / Precision -20°C … 150°C, 0°C … 650°C / ± 2°C or 2% of measured value
Screen type 3.5" colour TFT
Mode Infrared image, digital image, MIX image, image-in-image
Image function 1-32x digital zoom
Image-/Videoformat JPEG / MPEG-4
Memory Micro-SD card up to 8 GB
Ports USB type C, 1/4" tripod thread
Radio module operating data
WLAN standard: IEEE 802.11 b/g/n; Frequency band: 2.400 - 2.4835 GHz
(IEEE 802.11 b/g/n); Radio channels: Channel 9; Transmit power: 17 dBm
max.; Transmission rate: IEEE 802.11 b to 11 Mbps, IEEE 802.11 g/n to
54 Mbps (at 15 ± 2 dBm); Safety: open; Local server mode: IP address
192.168.230.1, HTTP, no DHCP; Port: 80
Operating conditions
-15°C … 50°C, humidity 10 … 90% rH, no condensation,
max. working altitude 2000 m above sea level
Storage conditions -20°C … 70°C, humidity 10 … 99% rH
Power supply / Charging time /
Operating time
Li-Ion pack battery 3,7V / 2,6Ah / 9,62Wh
approx. 4 h. / approx. 4 h
Dimensions (W x H x D) / Weight 95 x 230 x 112 mm / 530 g (incl. battery pack)
EU and UK directives and disposal
This device complies with all necessary standards for the free movement of goods within
the EU and the UK.
This product is an electric device and must be collected separately for disposal according
to the European and UKDirective on waste electrical and electronic equipment.
Further safety and supplementary notices at:
https://www.laserliner.com
Subject to technical alterations. (22W25)