Manual

ThermoCamera HighSense (Pro)
-20~150°C
0~650°C
Celcius (°C)
Fahrenheit (°F)
Kelvin (K)
Temperature range
Temperature unit
The default setting for the temperature range can be
selected in this menu. Choose between two ranges:
-20 - +150 °C (optimum for indoor and outdoor
thermal imaging of buildings) 0 - +650 °C (optimum
for industrial applications)
The unit of temperature can be set in this menu.
14.2
Measure Settings: Temperature range
14.1
Measure Settings: Temperature unit
OFF
Above MAX alarm
Below MIN alarm
Interval alarm
Alarm mode
The upper and low alarm levels can be activated
in the Alarm Mode menu.
The upper and lower alarm levels must be activated
to use the Alarm Range function.
The Alarm Range is dened by the threshold values
for the upper and lower alarm levels. The acoustic
alarm sounds if a temperature is measured which is
within these two threshold values, for example when
the temperature is 35 °C and the upper alarm is set
at 40 °C and the lower alarm at 30 °C.
14.3
Measure Settings: Alarm mode
45
EN