Manual
6
Alarm: Below MIN / above MAX alarm
Below MIN alarm
7.0
Parameter: Ambient temperature
Alarm
Inuences measurements taken with the thermal
imaging camera are affected by the ambient temperature.
This parameter compensates the inuence of the
ambient temperature on the measurement.
This can be set between 0 °C and 50 °C.
The alarm threshold values above and below the
specied temperature levels can be set in this menu.
Instructions for activating the alarm are provided in
Section 14.3.
Ambient Temperature
Settings: Set language, temperature units, date, time, etc., display the WLAN connection, select
CustomApps, automatic switch off and display information about the device.
Colour palettes: Several colour palettes are available to display the infrared temperatures.
Image mode: Select image mode from IR Thermal, MIX Image, Visible image, Auto Fusion
and Zoom.
Measuring device: Set the measurement points and areas.
Parameter: Before each use, check the relevant parameters for infrared measurement or adjust
them to the specic measuring situation to ensure accurate measurements. In doing so, please pay
particular attention to the general parameters with respect to the emissivity coefcient, distance to
target and ambient conditions.
Alarm: Set the alarm above and below the specied temperature level.
32
EN