Users Manual
8
6. Setting - Indicator
Danger / Caution Area Distance Setting
Restore Default Settings
Volume Control
· Press and hold SET1, STOP and SET2 buttons for 3 seconds.
· When the red LED flashes sequentially, press and hold the STOP button again for more than 2
seconds. The LED will turn off and the setting will be initialized. Reboot will take about 5
seconds.(Do not turn off until the green LED flashes.)
※ Default values after initialization : 4m for PT Danger Area / 8m for PT Caution Area
8m for VT Danger Area / 10m for VT Caution Area
SET 1 Button :
- Volume
SET 2 Button : + Volume
① Press and hold SET
1 and SET 2 buttons
simultaneously for 2
seconds or more.
④ When green LED
is on, set the
PT
Caution Area
by
pressing SET 1
or SET 2 buttons.
(Refer to "How to set
the distance" on the
following page.)
② Set the
PT Danger Area
by pressing SET 1 or
SET 2 buttons.(Refer to
"How to set the distance"
on the following page)
⑤ Press STOP button
to complete the
PT
Caution Area
setting.
③ Press STOP button
to complete the
PT
Danger Area
setting.
⑥ When red LED is on,
set the
VT Danger
/ Caution Area
by
pressing SET 1 or
SET 2
buttons
as the
previous process
②~⑤.
※ In a condition of normal operation
※ In a condition of normal operation
※ In case of malfunction
Set the distance in order by following below 4 steps.
Setting PT Danger Area ▶
Setting PT Caution Area ▶
Setting VT Danger Area ▶
Setting VT Caution Area ▶
Distance Setting Completed
※ Detailed setting of each function is available in SPDS Toolkit.
(Please refer to SPDS Toolkit user
manual)