Users Manual

8
6. Setting - Indicator
Danger / Caution Area Distance Setting
Restore Default Settings
Volume Control
· Press and hold SET1, STOP and SET2 buttons for 3 seconds.
· When the red LED flashes sequentially, press and hold the STOP button again for more than 2
seconds. The LED will turn off and the setting will be initialized. Reboot will take about 5
seconds.(Do not turn off until the green LED flashes.)
Default values after initialization : 4m for PT Danger Area / 8m for PT Caution Area
8m for VT Danger Area / 10m for VT Caution Area
SET 1 Button :
- Volume
SET 2 Button : + Volume
Press and hold SET
1 and SET 2 buttons
simultaneously for 2
seconds or more.
When green LED
is on, set the
PT
Caution Area
by
pressing SET 1
or SET 2 buttons.
(Refer to "How to set
the distance" on the
following page.)
Set the
PT Danger Area
by pressing SET 1 or
SET 2 buttons.(Refer to
"How to set the distance"
on the following page)
Press STOP button
to complete the
PT
Caution Area
setting.
Press STOP button
to complete the
PT
Danger Area
setting.
When red LED is on,
set the
VT Danger
/ Caution Area
by
pressing SET 1 or
SET 2
buttons
as the
previous process
②~⑤.
In a condition of normal operation
In a condition of normal operation
※ In case of malfunction
Set the distance in order by following below 4 steps.
Setting PT Danger Area ▶
Setting PT Caution Area ▶
Setting VT Danger Area ▶
Setting VT Caution Area ▶
Distance Setting Completed
Detailed setting of each function is available in SPDS Toolkit.
(Please refer to SPDS Toolkit user
manual)