Corp Computer Accessories User Manual

LaserSpeed 8000-3 Instruction Handbook
Part No. 93463 / Drawing No. 0921-01561 Page 88 of 221 Revision A (Sep 2007)
Imaje S4/S8
Pinout
Signal Imaje S4/S8 LaserSpeed
Signal A T1-8 8
Print Go T1-4 22
Signal Ground T1-1 and T1-3 11
User Voltage T1-7 20
Notes:
The programmable pulse output of the LaserSpeed needs to be set to
5000 or 10000 pulses/m depending on the setting in the Imaje printer.
The Index Pulse Output from the LaserSpeed needs to be set to 1
pulse per meter.