Pinout
Signal Domino A200 LaserSpeed
Signal A 2 15
Print Go 3 22
Signal Ground 1 11
User Voltage 4 20
Notes:
๎ Configure the LaserSpeed for the appropriate pulse per unit length.
The index pulse should be set to trigger at the appropriate rate (every 2
feet, every 1 meter, etc), and with a 20 ms pulse width.
๎ On the Domino A-Series printer, the Strobe Divide should be set to 1.
๎ There are two ports that are in parallel so it doesnโt matter which one is
used. The other port would not be used. The printer should be set for
EXTERNAL print and the REPEAT PRINTING should be turned off.