Twinner Lines
When mounting the gauge on a twinner line, the gauge should be positioned
far enough from the twinner that the twist is set. If the gauge is placed close to
the twinner, it may not be able to measure due to excessive vibration and the
spin imparted on the wire due to the twisting motion. Moving the gauge down
the line farther from the twinner may improve the gauge's ability to make
measurements.
Line Movemen
t
Near Twinne
r
Wires spin and
corkscrew (make it
look like wires are
not moving)
Near Takeu
p
Twist is set, wires not
spinning or corkscrewing.