Installation Manual

Larson Electronics LLC www.LarsonElectronics.com
9419 E US HWY 175, Kemp, TX 75143 - P: (800) 369-6671 - F: (903) 498-3364 - E: sales@magnalight.com
system enclosure, when they are integrated into a system, the EMC characteristics of the end system
must be re‐verified again.
Mechanical Specifications:
Model
DCP-11-12V
DCP-11-24V
Output
12V
24V
12.5A
6.3A
150W
151.2W
150mVp-p
150mVp-p
± 2.5%
± 1.0%
± 0.5%
± 0.5%
± 2.0%
± 0.5%
Input
100-277V AC
47-63Hz
PF>0.98/115V, PF>0.95/230V
92%
93.50%
1.7A/115V, 0.75A/230V
<0.75mA/240V
Protection
95~108%
Constant Current Limiting
14-17V
28-34V
100°C ± 10°C
Environment
-40°C to +70°C
20-95% RH non-condensing
-40°C to +80°C
10-95% RH
± 0.03%/°C (0-50°C)
10-500Hz, 5G 12min./1cycle