Datasheet

DATA SHEET
2170901
ETHERLINE
®
Y CAT.5e BK 2x2xAWG22/7
Valid from:
03.05.2011
Prepared by:
PNM – Jennifer Lehmann
Document: DB2170901EN
Page 2 of 2
Electrical data at 20°C
Loop resistance max. 115 Ω/km
Insulation resistance min. 5 GΩ*km
Mutual capacitance 800Hz 48 nom. nF/km
Characteristic impedance 1 up to 100 MHz 100±15
Operating peak voltage (not for purposes of power) 125 V
Surface transfer impedance 10 MHz 50 max. m
Ω/m
Test voltage (core/core/screen rms 50 Hz 1min) core/core 1000 V
core/screen 500 V
Frequency Attenuation NEXT
[MHz] max. [dB/100m] min. [dB]
1 2.1 65.3
4 4 56.3
10 6.3 50.3
16 8 47.2
20 9 45.8
31.25 11.4 42.9
62.5 16.5 38.4
100 21.3 35.3
The electrical requirements acc. to DIN EN 50288-2-1
Mechanical and thermal characteristics
Conductor material acc. to DIN EN 13602 Cu-ETP-A...
Screen material acc. to DIN EN 13602 Cu-ETP-A...-B
Flame retardant acc. to IEC 60332-1-2
Permissible tensile strength max. 100 N
during installation
Permissible temperature range single -40 up to +80 °C
repeated -10 up to +70 °C
Min. bending radius allowed single 10 X ø
repeated 15 X ø
General properties
RoHS standard procedure The cable is compliant to RoHS standard procedure (2002/95/EG)
REACH/WEEE The cable is compliant to prescription (EG) # 1907/2006 (REACH)