Datasheet
DATA SHEET
0152003
DIN compensating cable KN 1 L-SIL 2x1,5
valid from :
01.12.2008
Originator: Frank Hörtnagl / PD-KL
Approved: Werner Körner / TE
Document: DB0152003EN page 1 of 1
All deviations from this specification are subject to explicit consent of U.I.LAPP GmbH. All rights reserved acc. to DIN 34.
No.: 0019/0408
Application
The compensating cable KN 1 L-SIL 2 x 1,5 mm² are silicone insulated cores which transmit the thermoelectric
voltage of NiCr/Ni thermocouples. They are for fixed installation in dry and damp rooms and may only be installed
outdoors with mechanical and UV protection and in observation of the max. permitted temperature range.
Design
Conductor 1,5 mm² (48 x 0,20 mm)
Conductor material KCA alloying, accuracy class 2 according DIN 43722
Positive conductor: Fe (iron)
Negative conductor: CuNi (cupronickel)
Core insulation Silicone compound
Core identification Positive conductor: red
Negative conductor: green
Core layering Cores twisted together
Outer sheath No outer sheath
Electrical properties
Limiting deviation class 2 ± 100 µV (± 2,5 °C) / m easuring point temperature +900 °C
Mechanical and thermal properties
Temperature range occasional flexing: -25 °C up t o +180 °C
Minimum bending radius occasional flexing: 12 x cable diameter