PRODUCT INFORMATION
UNITRONIC® BUS LD
UL/CSA type CMX acc. to UL 444
and CSA C22.2 no. 214-02
Flame retardant acc. to IEC 60332-1-2
Product Make-up
Stranded conductor, bare, 7-wire
Core insulation: PE
Colour code DIN 47100
Overall screening of braided tinned-copper strands
Outer sheath: PVC, violet (RAL 4001)
Technical Data
Classification ETIM 5: ETIM 5.0 Class-ID: EC000830
ETIM 5.0 Class-Description: Data cable
Classification ETIM 6: ETIM 6.0 Class-ID: EC000830
ETIM 6.0 Class-Description: Data cable
Mutual capacitance: Flexible use: 10 x outer diameter
Peak operating voltage: (not for power applications) 250 V
Conductor resistance: (loop): max. 186 ohm/km
Minimum bending radius: Fixed installation: 8 x outer diameter
Test voltage: Core/core: 1500 V rms
Characteristic impedance: 100 - 120 Ohm
Temperature range: Fixed installation: -40°C to +80°C
Flexing: -5°C to +70°C
Note
Unless specified otherwise, the shown product values are nominal values. Detailed values (e.g. tolerances) are available upon
request.
Copper price basis: EUR 150/100 kg. Refer to catalogue appendix T17 for the definition and calculation of copper-related
surcharges.
Please find our standard lengths at: www.lappkabel.de/en/cable-standardlengths
Packaging size: coil ≤ 30 kg or ≤ 250 m, otherwise drum
Please specify the preferred type of packaging (e.g. 1 x 500 m drum or 5 x 100 m coils).
Modubus is owned by the Modbus-IDA Organisation. SUCOnet P is a registered trademark of the Moeller Group. Modulink P is
a registered trademark of Weidmüller GmbH & Co. VariNet is a registered trademark of Pepperl+Fuchs GmbH.
Photographs and graphics are not to scale and do not represent detailed images of the respective products.
Prices are net prices without VAT and surcharges. Sale to business customers only.
Last Update (16.05.2019) 2 / 3
©2019 Lapp Group - Technical changes reserved
Product Management www.lappkabel.de
You can find the current technical data in the corresponding data sheet.
PN 0456 / 02_03.16