Data Sheet
U.I. Lapp 
GmbH 
DATA SHEET 
ETHERLINE
®
 P Cat. 5e 2x2x24/1 AWG 
DB2170281 
valid from: 25.03.2014 
Originator: RAWE/PDC 
approved: HAPF/PDC 
Document:  DB2170281 
page 2 of 2 
All rights reserved acc. to DIN ISO 16016. 
PD 0019/2.2_11.10DE 
Transmission properties 
Transmission properties acc. to IEC 61156-5: abstract of the minimum requirements shown in the table: 
f  
[MHz] 
Attenuation 
[dB/100m] 
NEXT [dB] 
PS NEXT 
[dB] 
EL FEXT 
[dB/100m] 
PS EL FEXT 
[dB/100m] 
RL 
1 
2,1 
65,3 
62,3 
- 
- 
- 
4 
4,1 
56,3 
53,3 
52,0 
49,0 
- 
10 
6,5 
50,3 
47,3 
44,0 
41,0 
- 
16 
8,3 
47,2 
44,2 
39,9 
36,9 
- 
31,25 
11,7 
42,9 
39,9 
34,1 
31,1 
23,6 
62,5 
17,0 
38,4 
35,4 
28,1 
25,1 
21,5 
100 
22,0 
35,3 
32,3 
24,0 
21,0 
20,1 
Mechanical and thermal properties 
Minimum bending radius 
7,5 x cable Ø  
Permissible temperature range 
 moved (VDE): -5˚ C up to +50˚ C 
fixed installation (VDE): -30˚ C up to +80˚ C 
 moved (UL): -5˚ C up to +80˚ C 
 fixed installation (UL): -30˚ C up to +80˚ C 
Halogen free 
acc. to VDE 0472-815 
Flame retardant 
acc. to IEC 60332-1-2 
General requirements 
Dangerous and forbidden substances acc. to RoHS directive (2011/65/EU) 
are not allowed to the manufacturing. 