Datasheet
1123000
DATA SHEET
valid from:
12.12.2019
Creator: LABU / PDC
Released: ALTE / PDC
Document: DB1123000EN
Version: 15
Page 1 of 2
We reserve all rights according to DIN ISO 16016.
PD 0019/05_04.18EN
Application
rket, for
occasional flexible use and fixed installation subject to normal mechanical load conditions.
They are also suitable for use in dry or damp areas. Considering the temperature range, a temporary outdoor use is possible. They are
suitable for occasional, non-automated movements. The maximum tensile load is 15 N/mm² of conductor cross-section during installation
and operation. Compulsory guidance is not permitted.
osed to high
risk of fire hazards. In the event of a fire minimal toxic and no corrosive gases occur.
Application range: Public buildings, airports, railway stations, plant engineering and construction, air conditioning systems
Stage applications
USE according to UL: FRPE sheathed cable for internal wiring of appliances
Design
Design
acc. to UL AWM 758
based on EN 50525-3-11 resp. VDE 0285-525-3-11
EN 50525-2-51 resp. VDE 0285-525-2-51
Certification
UL AWM Style 21217* (File No. E63634), UL 758
DNV GL (Certificate No. TAE00002RJ)
VDE certified: Supply cable with improved characteristics in the case of fire
EN 13501-6 and EN 50575
Classification of fire behaviour
(article/dimension range see www.lappkabel.com/cpr)
*Style change: UL Style 21089 replaced by Style 21217 (approx. February 2018)
Conductor
fine wire strands of bare copper, acc. to IEC 60228 resp. VDE 0295, Class 5
Insulation
halogen free compound TI6 acc. to
EN 50363-7 resp. VDE 0207-363-7
Core identification code
acc. to VDE 0293-1, with or without GN/YE ground conductor
black cores with white numbers acc. to DIN EN 50334 resp. VDE 0293-334
Stranding
cores are stranded in layers
Taping
non-woven wrapping optional
Outer sheath
halogen free compound TM7 acc. To EN 50363-8 resp. VDE 0207-363-8
Colour: Silver Grey, similar RAL 7001
dlsafjlöj f
Electrical properties at 20°C
Nominal voltage
VDE U₀/U: 300/500 V
UL: 600 V
Test voltage
core /core: 4000 V AC
Mechanical and thermal properties
Minimum bending radius
occasional flexing: 15 x outer diameter
fixed installation: 4 x outer diameter
Temperature range
occasional flexing (VDE): -25˚C up to +70˚C max. conductor temp.
occasional flexing (UL): up to +75˚C max. conductor temp.
fixed installation (VDE): -40˚C up to +80˚C max. conductor temp.
fixed installation (UL): up to +75˚C max. conductor temp.
Flammability
acc. to IEC 60332-1-2 resp. VDE 0482-332-1-2
no flame-propagation
acc. to IEC 60332-3-22 resp. VDE 0482-332-3-22
acc. to IEC 60332-3-24 resp. VDE 0482-332-3-24 or
acc. to IEC 60332-3-25 resp. VDE 0482-332-3-25
Halogen free
acc. to IEC 60754-1 resp. VDE 0482-754-1
Corrosivity of gases
acc. to IEC 60754-2 resp. VDE 0482-754-2
Smoke density
acc. to IEC 61034-2 resp. EN 61034-2
Toxicity
acc. to NES 713-3, EN 50306-1 (≤ 3)
UV resistance
acc. to EN 50620 resp. VDE 0285-620
acc. to EN ISO 4892-2-2013, method A (change of colour allowed)