Data Sheet
U.I. Lapp
GmbH
DATA SHEET
ÖLFLEX
®
FD 891
DB 1026003
valid from: 2014-02-21
Originator: KASC / PDC
approved: HAPF / PDC
Document: DB1026003EN
Page 1 of 1
All rights reserved acc. to DIN ISO 16016.
PD 0019/2.2_11.10EN
Application
ÖLFLEX-FD
891 cables are high flexible cables for power chains for the European, Northern American and Canadian market
for flexible use and fixed installation for light and medium mechanical use. They are for use in dry, damp and wet rooms.
Under following to the indicate temperature range is an use outside possible. Continuous, busy movements, usage of these
cables in moving cable carriers, respectively on motor drum guidance or under a strain of more than 15 N/mm² is not al-
lowed. ÖLFLEX-FD
891 cables are increased oil resistant and at room temperature generally resistant against acids and
caustics solutions.
USE according to UL: PVC sheathed cables for external interconnection or internal wiring of electronic equipment.
USE according to CSA: cables for internal or external interconnection with or without mechanical use.
Application range: in power chains or moving machine parts, plant engineering, machine tools
Design
Design acc. to UL AWM Style 10012, UL AWM Style 21098, CSA AWM IIA/B
and based on
EN 50525-2-51 resp. VDE 0285-525-2-51 / HD 21.13 S1+A1 resp. VDE 0281-13
DIN 57250 resp. VDE 0250
Approvals UL AWM Style 21098 or UL AWM Style 2587 (File No. E63634)
CSA AWM IA/B IIA/B (File No. LL 53776)
Conductor fine wire strands of bare copper acc. to IEC 60228 resp. VDE 0295, Class 6
Core insulation PVC compound (UL/CSA 90°C rating)
Core identification acc. to VDE 0293-1, with or without GN/YE ground conductor
black cores with white numbers acc. to DIN EN 50334 resp. VDE 0293-334
Outer sheath PVC compound (UL/CSA 90°C rating) with increased requests to Lapp specification
colour: black, similar RAL 9005
Electrical properties
Nominal voltage IEC U
0
/ U: 300 / 500 V
UL/CSA: 600 V
Test voltage 4000 V AC
Mechanical and thermal properties
Min. bending radius occasional flexing: 7,5 x outer diameter
fixed installation: 4 x outer diameter
Number of bending/unbening
cycles 5 mio. cycles
Travel distance 10 m
Temperature range occasional flexing: -5 °C up to +90 °C (UL/CSA) max. conductor temp.
fixed installation: -40 °C up to +90 °C (UL/CSA) max. conductor temp.
Oil resistance acc. to IEC 60811resp. VDE 0473-811 (90°C, 7d)
80°C rating acc. to UL 758; CSA C22.2 No. 210-05
Flammability flame retardant acc. to IEC 60332-1-2
UL: vertical flame test VW-1, CSA: FT1
Tests acc. to IEC 60811, EN 50395, EN 50396
EC-Directives This cable is conform to the EC-Directives 2006/95/EC (Low Voltage Directive)
and 2011/65/EU (RoHS, Restriction of the use of certain hazardous substances).