User's Guide
Configuration via Serial Mode or Telnet Port
WiBox™ User Guide 56
Each entry contains the IP address and the port number.
The hostlist is disabled for Manual and Modem Modes. The unit
does not accept a data connection from a remote device when
the hostlist option is enabled.
Figure 4-7. Hostlist Option
To enable the hostlist:
1. Enter a Connect Mode of 0x20 (2X), where X is any digit. The menu shows you
a list of current entries already defined in the product.
2. To delete, modify, or add an entry, select Yes. If you enter an IP address of
0.0.0.0, that entry and all others after it are deleted.
3. After completing the hostlist, repeat the previous step if necessary to edit the
hostlist again.
4. For Retrycounter, enter the number of times the Lantronix unit should try to
make a good network connection to a hostlist entry that it has successfully
ARPed. The range is 1-15, with the default set to 3.
5. For Retrytimeout, enter the number of seconds the unit should wait before
failing an attempted connection. The time is stored as units of milliseconds in the
range of 1-65535. The default setting is 250.
d) Datagram Type
Directed UDP When selecting this option, you are prompted for the Datagram type.
Enter 01 for directed or broadcast UDP.