User's Guide

Web-Manager Configuration
WiBox™ User Guide 43
Apply Defaults
Click the Apply Defaults button to reset the unit’s Channel 1 configuration, Channel
2 configuration, Security, and Expert settings to the factory default settings. The
server configuration settings for IP address, gateway IP address, netmask, and
WLAN remain unchanged. The specific settings that this option changes are listed
below:
CHECK THESE
Channel 1 Configuration
Baudrate
9600
I/F Mode
4C (1 stop bit, no parity, 8 bit, RS-232C)
Port No
10001
Connect Mode C0 (always accept incoming connection; no active
connection startup)
Hostlist Retry Counter
3
Hostlist Retry Timeout
250 (msec)
Send Character
0x0D (CR)
All other parameters
0
Channel 2 Configuration
Baudrate
9600
I/F Mode
4C (1 stop bit, no parity, 8 bit, RS-232C)
Port No
10002
Connect Mode C0 (always accept incoming connection; no active
connection startup)
Hostlist Retry Counter
3
Hostlist Retry Timeout
250 (msec)
Send Character
0x0D (CR)
All other parameters
0
WLAN Settings
Enable WLAN
(Y) Yes
Topology
Infrastructure
Network Name
LTRX_IBSS
Channel
11
Security
0 (none)