58 WiPortâ„¢ User Guide
This setting defaults to the N (No) option. The Y (Yes) option disables access to
Setup Mode by Telnet (port 9999). It only allows access locally via the web pages
and the serial port of the unit.
Disable Telnet Setup (N) ? _
Disable TFTP Firmware Upgrade
This setting defaults to the N (No) option. The Y (Yes) option disables TFTP for
network firmware upgrades.
Disable TFTP Firmware Update (N) : _
With this option, download firmware upgrades over the serial port using
DeviceInstaller’s Recover Firmware procedure (see page 70).
Disable Port 77FE (Hex)
Note: Disabling both Telnet Setup and Port 77FE prevents users from
accessing the setup menu from the network.
Port 77FE is used by DeviceInstaller, Web-Manager, and custom programs to
configure the unit remotely. If required, disable this capability for security purposes.
Disable Port 77FEh (N) ? _
The default setting is the N (No) option, which enables remote configuration. As a
result, configure the unit by using DeviceInstaller, web pages, Telnet, or serial
configuration.
The Y (Yes) option disables remote configuration and web sites.
Note: The Y (Yes) option disables many of the GUI tools for configuring the
unit, including the embedded Web-Manager tool.
Disable Web Server
The Y (Yes) option disables the web server. This setting defaults to the N (option).
Disable Web Server (N) ? _
Disable Web Setup
The Y (Yes) option disables configuration via the Web-Manager. This setting defaults
to the N (option).
Disable Web Setup (N) ? _
Disable ECHO Ports
This setting controls whether the serial port echoes characters it receives. The
current value is displayed in parentheses.
Disable ECHO ports (Y) ? _
Enable Enhanced Password
This setting defaults to the N (option), which permits a 4-character password