Configuration using Web-Manager
WiPort™ User Guide 31
Remote Port
Enter the port number of the remote device.
Remote Host
Enter the IP address of the remote device.
Change Address Table
Field enabled when Datagram Type is set to FD. Enter values
between 1-255 to identify units on the local network of device
servers.
Email Configuration
The unit sends an Email to multiple recipients when a specific trigger event occurs.
There are three separate triggers, based on any combination of the configurable pins
when selected as user I/O functions. Optionally, use a two-byte serial string to initiate
a trigger. Each trigger is independent of the others. Each condition within an
individual trigger must be met before the unit will send the Email.
To configure the WiPort’s email settings:
1. From the main menu, select Email to open the Email Settings window.
Figure 4-8. Email Settings
2. Configure the following fields:
Server IP Address
Enter the IP address of the mail server.
Domain Name
Enter the Email server’s domain name.
Unit Name Enter the username used by the WiPort to send Email
messages.