Configuration using Web-Manager
30 WiPortâ„¢ User Guide
Inactivity Timeout Use this parameter to set an inactivity timeout. The unit drops
the connection if there is no activity on the serial line before
the set time expires. Enter time in the format mm:ss, where m
is the number of minutes and s is the number of seconds. To
disable the inactivity timeout, enter 00:00.
Connection Settings - UDP
To configure a channel’s UDP settings:
1. From the main menu, click Connection for either Channel 1 or Channel 2 to
display the Connection Settings page for the selected channel.
2. In the available fields, enter the following information:
Connect Protocol
Protocol Select UDP from the pull down menu.
Figure 4-7. UDP Connection Settings
Datagram Mode
Datagram Type Configures remote IP or network broadcast address and the
remote port. Enter 01 for directed or broadcast UDP.
Accept Incoming Select Yes to accept incoming UDP datagrams.
Endpoint Configuration
Local Port
Enter the local port number.