UDS1100 User Guide Part Number 900-417 Revision A February 2006
Copyright & Trademark © 2006, Lantronix. All rights reserved. No part of the contents of this book may be transmitted or reproduced in any form or by any means without the written permission of Lantronix. Printed in the United States of America. Ethernet is a trademark of XEROX Corporation. UNIX is a registered trademark of The Open Group. Windows 95, Windows 98, Windows 2000, and Windows NT are trademarks of Microsoft Corp. Netscape is a trademark of Netscape Communications Corporation.
Contents 1: Using This Guide 7 Purpose and Audience _______________________________________________ 7 Chapter Summary ___________________________________________________ 7 Additional Documentation _____________________________________________ 8 2: Introduction 9 Applications ________________________________________________________ 9 Application Examples ________________________________________________ 9 Protocol Support ___________________________________________________ 11 Additional Features ________
Contents Serial Port Connection ___________________________________________ 36 Exiting Setup Mode _________________________________________________ 36 6: Setup Mode: Server Configuration Server Configuration (Option 0)________________________________________ IP Address ________________________________________________________ Set Gateway IP Address _____________________________________________ Netmask: Number of Bits for Host Part __________________________________ Change Telnet Configuration Password _____
Contents Disable TFTP Firmware Update ____________________________________ Disable Port 77FE (Hex) __________________________________________ Disable Web Server _____________________________________________ Disable Web Setup ______________________________________________ Disable ECHO Ports _____________________________________________ Enable Enhanced Password _______________________________________ Default Settings (Option 7) ___________________________________________ Channel 1 Configuration Defaults _____
Contents D: Compliance and Disclaimer 80 Index 82 Figures Figure 2-1. Serial Tunneling Example _____________________________________ Figure 2-2. Direct TCP/IP or Redirector Configuration ________________________ Figure 2-3. Sample Hardware Address ____________________________________ Figure 3-1. UDS1100 Connected to Serial Device and Network _________________ Figure 4-1. Lantronix Web-Manager ______________________________________ Figure 4-2.
1: Using This Guide Purpose and Audience This guide provides the information needed to configure, use, and update the UDS1100 device server. It is for system administrators and those responsible for installing and maintaining the UDS. Chapter Summary The remaining chapters in this guide include: 2: Introduction Describes the main features of the UDS and the protocols it supports.
1: Using This Guide B: Binary to Hexadecimal Conversions Provides instructions for converting binary values to hexadecimals. Additional Documentation The following information is available on the product CD or the Lantronix Web site: www.lantronix.com UDS1100 Quick Start Provides the steps for getting the UDS1100 up and running. DeviceInstaller Online Help Provides instructions for using the Windows-based utility to configure the UDS1100 and other Lantronix device servers.
2: Introduction The UDS1100 is a single-port device server that provides a quick, simple, and costeffective way to bring the advantages of data accessibility and remote management to devices not currently connected to a network. Applications The UDS family of Device Servers allows serial devices, such as those listed below, to connect and communicate over Ethernet networks using the IP protocol family (TCP for connection-oriented stream applications and UDP for datagram applications).
2: Introduction Figure 2-1. Serial Tunneling Example The Com Port Redirector software included on the product CD simplifies the integration process by extending the functionality of COM-port-based Windows™ applications. Virtual COM ports, mapped to remote device servers on the network, can replace direct serial connections. Figure 2-2.
2: Introduction Protocol Support The UDS uses the Internet Protocol (IP) for network communications and the Transmission Control Protocol (TCP) to assure that no data is lost or duplicated and that everything sent to the connection arrives correctly at the target. Supported protocols include: ARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, and SNMP for network communications. TCP, UDP, and Telnet for connections to the serial port. TFTP for firmware updates.
2: Introduction Product Information Label The product information label on the underside of the unit contains the following information about your specific unit: Bar code Serial number Product ID (name) Product description Hardware address (also referred to as the Ethernet or MAC address) The first three bytes of the hardware address are fixed and read 00-20-4A, identifying the unit as a Lantronix product. The fourth, fifth, and sixth bytes are unique numbers assigned to each unit.
3: Getting Started This chapter describes how to get your UDS up and running in the shortest possible time. Package Contents Verify and inspect the contents of the UDS1100 package using the following list. If any item is missing or damaged, contact your place of purchase immediately.
3: Getting Started Installing the UDS Figure 3-1. UDS1100 Connected to Serial Device and Network To install the unit: Complete the following steps in order. Refer to the numbers in the figure above. Note: See the sections that follow for details about connectors and pinouts. 1. Connect a serial device to your unit. 2. Connect an Ethernet cable to the RJ45 port. 3. Supply power to your unit using the power supply that was included in the packaging.
3: Getting Started Required Information Before configuring the UDS, have the following information available: Hardware Address Take note of the unit’s hardware address (also known as the Ethernet or MAC address). It is on the product label, in the format: 00-20-4a-XX-XX-XX, where the XXs are unique numbers assigned to the product (see Product Information Label on page 12). Hardware Address: 00-20-4a-_____-_____-_____ IP Address The UDS must have a unique IP address on your network.
3: Getting Started Assigning the IP Address: DeviceInstaller This chapter covers the steps for getting the UDS1100 device server online and for viewing its current configuration. Note: DeviceInstaller online Help provides more detailed information on using DeviceInstaller. Installing DeviceInstaller To use the DeviceInstaller utility, first install it from the product CD. 1. Insert the product CD into your CD-ROM drive. The Lantronix UDS1100 DeviceInstaller window displays. 2.
3: Getting Started 7. Select the device from the main window list and select Ping from the Tools menu. The Ping Device dialog box shows the IP address of the selected unit. 8. From the Tools menu, click the Ping button. The results display in the Status window. Click the Clear Status button to clear the window so you can ping the device again.
3: Getting Started Type Non-configurable field. Displays the device type as UDS1100. ID Non-configurable field. Displays the UDS1100’s ID embedded within the box. Hardware Address Non-configurable field. Displays the UDS1100’s hardware (or MAC) address. Firmware Version Non-configurable field. Displays the firmware currently installed on the UDS1100. Extended Firmware Version Non-configurable field. Displays the full version nomenclature of the firmware. Online Status Non-configurable field.
3: Getting Started Supports Configurable Pins Non-configurable field. Displays False. Supports Email Triggers Non-configurable field. Displays False. Supports AES Data Stream Non-configurable field. Displays False. Supports 485 Non-configurable field. Displays True. The UDS1100 supports the RS-485 protocol. Supports 920K Baudrate Non-configurable field. Displays False. UDS1100 supports baud rates up to 230 Kbaud. Supports HTTP Server Non-configurable field. Displays True.
3: Getting Started 5. Do one of the following: Continue with 5: Configuration via Telnet or Serial Port (Setup Mode). Select 9 to save and exit Setup Mode. The unit performs a power reset.
4: Configuration Using Web-Manager You must configure the unit so it can communicate on a network with your serial device. For example, you must set the way the unit will respond to serial and network traffic, how it will handle serial packets, and when to start or close a connection. The unit’s configuration is stored in nonvolatile memory and is retained without power. You can change the configuration at any time. The unit performs a reset after you change and store the configuration.
4: Configuration Using Web-Manager Figure 4-1. Lantronix Web-Manager The main menu is in the left pane of the Web-Manager window. Network Configuration The unit’s network values display when you select Network from the main menu. The following sections describe the configurable parameters on the Network Settings page. Figure 4-2.
4: Configuration Using Web-Manager Automatic IP Address Configuration An IP address can be assigned automatically. You then enter related network settings. To assign an IP address automatically: 1. On the main menu, click Network. 2. Select Obtain IP address automatically. 3. Enter the following (as necessary): BOOTP Select Enable to permit the Bootstrap Protocol (BOOTP) server to assign the IP address from a pool of addresses automatically. Enable is the default.
4: Configuration Using Web-Manager 4. When you are finished, click the OK button. 5. On the main menu, click Apply Settings. Ethernet Configuration You must specify the speed and direction of data transmission. To specify how data will be transmitted: 1. On the main menu, click Network. 2. Enter the following (as necessary): Auto Negotiate With this option, the Ethernet port auto-negotiates the speed and duplex with the hardware endpoint to which it is connected. This is the default.
4: Configuration Using Web-Manager Figure 4-3. Server Settings To configure the UDS1100’s device server settings: 1. On the main menu, click Server. 2. Configure or modify the following fields: Server Configuration Telnet Password Enter the password required for Telnet access. Retype Password Re-enter the password required for Telnet access. Advanced ARP Cache Timeout (secs) When the unit communicates with another device on the network, it adds an entry into its ARP table.
4: Configuration Using Web-Manager MTU Size The Maximum Transmission Unit (MTU) is the largest physical packet size a network can transmit for TCP and UDP. Enter between 512 and 1400 bytes. The default setting is 1400 bytes. 3. When you are finished, click the OK button. 4. On the main menu, click Apply Settings. Host List Configuration The UDS1100 scrolls through the host list until it connects to a device listed in the host list table.
4: Configuration Using Web-Manager Retry Timeout Enter the duration (in seconds) the UDS1100 should abandon attempting a connection to the host list. The default setting is 250. Host Information Host Address Enter or modify the host’s IP address. Port Enter the target port number. 3. When you are finished, click the OK button. 4. On the main menu, click Apply Settings. Channel 1 Configuration The Channel 1 configuration defines how the serial port responds to network and serial communication.
4: Configuration Using Web-Manager Channel 1 Disable Serial Port When selected, disables communication through the serial port. The serial port is enabled by default. Note: This feature is not available on single port device servers. Port Settings Protocol From the drop-down menu, select the protocol type for the selected channel. The default setting is RS232. Flow Control Flow control manages data flow between devices in a network to ensure it is processed efficiently.
4: Configuration Using Web-Manager Match Bytes Use to indicate the end of a series of data to be sent as one group. Set this value to 00 if specific functions are not needed. Send Frame Only After the detection of the byte sequence, indicates whether to send the data frame or the entire buffer. Select Yes to send only the data frame. The default setting is No. Send Trailing Bytes Select the number of bytes to send after the end-of-sequence characters. The default setting is None.
4: Configuration Using Web-Manager Figure 4-6. TCP Connection Settings 2. In the available fields, enter or modify the following information: Connect Protocol Protocol From the drop-down menu, select TCP. Connect Mode: Passive Connection Accept Incoming Select Yes to accept incoming connections. The default setting is Yes. Password Required Determines whether a password is required for an incoming passive connection. This field is not available when a password is set for Telnet mode.
4: Configuration Using Web-Manager Connect Mode: Active Connection Active Connect Select None (default) to disable Active Connect. Otherwise, indicate the connection type from the drop-down list: With Any Character: Attempts to connect when any character is received from the serial port. With Active Mdm Ctrl In: Accepts external connection requests only when the modem_control_in input is asserted.
4: Configuration Using Web-Manager Use Hostlist If this option is set to True, the device server scrolls through the host list until it connects to a device listed in the host list table. Once it connects, the unit stops trying to connect to any others. If this connection fails, the unit continues to scroll through the table until it connects to another IP in the host list. The host list is disabled for Manual Mode and for Modem Mode.
4: Configuration Using Web-Manager Figure 4-7. UDP Connection Settings Connect Protocol Protocol Select UDP from the drop-down menu. Datagram Mode Datagram Type Configures the remote IP or network broadcast address and the remote port. Enter 01 for directed or broadcast UDP. The default setting is 00. Accept Incoming Select Yes to accept incoming UDP datagrams. The default setting is Yes. Endpoint Configuration Local Port Enter the local port number.
4: Configuration Using Web-Manager Device Address Table The table is enabled when Datagram Type is set to FD. Enter values between 1 and 255 to identify units on the local network of device servers. Note: Lantronix Tech Support supports Datagram type 01. Datagram Type FD is for OEM use. 3. When you are finished, click the OK button. 4. On the main menu, click Apply Settings. Apply Settings 1. To save and apply the configuration changes to the device server, click the Apply Settings button.
5: Configuration via Telnet or Serial Port (Setup Mode) You must configure the unit so it can communicate on a network with your serial device. As an alternative to using a web browser, as described in the previous chapter, you can use the following procedures remotely or locally: Use a Telnet connection to configure the unit over the network. Use a terminal or terminal emulation program to access the serial port locally.
5: Configuration via Telnet or Serial Port (Setup Mode) Figure 5-1. MAC Address 3. To enter Setup Mode, press Enter within 5 seconds. The configuration settings display, followed by the Change Setup menu. Figure 5-2. Setup Menu Options 4. Select an option on the menu by entering the number of the option in the Your choice ? field and pressing Enter. 5. To enter a value for a parameter, type the value and press Enter, or to confirm a current value, just press Enter. 6.
6: Setup Mode: Server Configuration This chapter explains how to configure the network settings. Note: Current values display in parentheses. Server Configuration (Option 0) The unit’s basic network parameters display when you select Server configuration (option 0). The IP Address, Set Gateway IP Address, and Netmask fields display the current values. Figure 6-1. Network Settings IP Address : (000) .(000) .(000) .
6: Setup Mode: Server Configuration default setting is N (No), meaning the gateway address has not been set. To set the gateway address, type Y and enter the address. Set Gateway IP Address (N) ? Y Gateway IP addr (000) (000) (000) (000)_ Netmask: Number of Bits for Host Part A netmask defines the number of bits taken from the IP address that are assigned for the host part.
6: Setup Mode: Server Configuration There are three methods for assigning DHCP names to the unit. Default DHCP Name: If you do not change the DHCP name, and you are using an IP of 0.0.0.0, then the DHCP name defaults to XX.XX.XX.XX (XXXXXX is the last 6 digits of the MAC address shown on the label on the bottom/side of the unit). For example, if the MAC address is 00-20-4A-12-3456, then the default DHCP name is C123456. Custom DHCP Name: You can create your own DHCP name.
7: Setup Mode: Channel Configuration This chapter explains how to configure the serial port. Notes: Current values display in parenthesis. You must enter some values in hexadecimal notation. (See B: Binary to Hexadecimal Conversions.) Channel 1 (Option 1) Select Channel 1 (option 1) from the Change Setup menu to define how the serial port responds to network and serial communications. The following sections describe the configurable parameters within the Channel configuration menu. Figure 7-1.
7: Setup Mode: Channel Configuration I/F (Interface) Mode The Interface (I/F) Mode is a bit-coded byte entered in hexadecimal notation. The default setting is 4C. Figure 7-2. Interface Mode I/F Mode (4C) ? _ The following table displays available I/F Mode options: Note: All bit positions in the table that are blank represent “don’t care” bits for that particular option, which can be set to either a 0 or 1 value. Table 7-1.
7: Setup Mode: Channel Configuration Use the following table to select flow control options: Table 7-3. Flow Control Options Flow Control Option Hex No flow control 00 XON/XOFF flow control 01 Hardware handshake with RTS/CTS lines 02 XON/XOFF pass characters to host 05 Port Number The setting represents the source port number in TCP connections. It is the number that identifies the channel for remote initiating connections. Port No (10001) ? _ The default setting for Port 1 is 10001.
7: Setup Mode: Channel Configuration Table 7-5.
7: Setup Mode: Channel Configuration b) Response Character Response A single character is transmitted to the serial port when there is a change in connection state: C = connected, D = disconnected, N = host unreachable. This option is overridden when the Active Start Modem Mode or Active Start Host List is in effect. Default setting is Nothing (quiet). c) Active Startup No Active Startup Does not attempt to initiate a connection under any circumstance. Default setting.
7: Setup Mode: Channel Configuration Figure 7-3. Manual Connection Address Example Command String Result if remote IP is 129.1.2.3 and remote port is 1234 C121.2.4.5/1 Complete override; connection is started with host 121.2.4.5, port 1. C5 Connects to 129.1.2.5, port 1234. C28.10/12 Connects to 129.1.28.10, port 12. C0.0.0.0/0 Enters Monitor Mode.
7: Setup Mode: Channel Configuration To enable the hostlist: 1. Enter a Connect Mode of 0x20 (2X), where X is any digit. The menu shows you a list of current entries already defined in the product. 2. To delete, modify, or add an entry, select Yes. If you enter an IP address of 0.0.0.0, that entry and all others after it are deleted. 3. After completing the hostlist, repeat the previous step if necessary to edit the hostlist again. 4.
7: Setup Mode: Channel Configuration Data Echo & Modem Response Full Verbose: The unit echoes modem commands and responds to a command with a message string shown in the table below. Numeric Response: The unit echoes modem commands and responds to a command with a numeric response. Modem Responses Only Full Verbose: The unit does not echo modem commands and responds to a command with a message string shown in the table below.
7: Setup Mode: Channel Configuration When an active connection is in effect, the unit terminates the connection if it receives the following sequence from the attached serial device: No serial data is received for one second. The character sequence +++ is received, with no more than one second between each two characters. No serial data is received for one second after the last + character. At this time, the unit responds affirmatively per the selected echo/response mode.
7: Setup Mode: Channel Configuration Send the Escape Sequence (+++) in Modem Mode Send ‘+++’ in Modem Mode (Y) ? _ Disable or enable the UDS1100’s ability to send the escape sequence. The default setting is Y (Yes) (send the escape sequence). Auto Increment Source Port Auto increment source port (N) ? _ Y (Yes) auto increment the source port. The UDS1100 increments the port number used with each new connection. Remote IP Address This is the destination IP address used with an outgoing connection.
7: Setup Mode: Channel Configuration Table 7-7. Disconnect Mode Options Disconnect Mode Option 7 (6) 1 Disconnect with DTR drop Ignore DTR Telnet mode and terminal type setup (1) 6 5 4 3 2 0 0 1 Channel (port) password (2) 1 Hard disconnect (3) 0 Disable hard disconnect 1 State LED off with connection (4) Disconnect with EOT (^D) (5) 1 1 1 (1) The UDS sends the "Terminal Type" upon an outgoing connection.
7: Setup Mode: Channel Configuration Table 7-8.
7: Setup Mode: Channel Configuration Option 7 6 5 4 3 2 1 0 Send Characters 2-Byte Send Character Sequence Send Immediately After Send chars 1 1 Packing Interval Packing Interval defines how long the unit should wait before sending accumulated characters. This wait period is between successive network segments containing data. For alternate packing, the default interval is 12 ms.
7: Setup Mode: Channel Configuration disables the recognition of the characters. Alternatively, the unit can interpret two characters as a sequence (see Pack Control on page 51). The default setting is 00. Telnet Terminal Type This parameter displays only if you enabled the terminal type option in Disconnect Mode. With this option enabled, you can use the terminal name for the Telnet terminal type. Enter only one name.
8: Setup Mode: Advanced Settings Expert Settings (Option 5) Note: You can change these settings using Telnet or serial connections only, not on the Web-Manager. Caution: Changing the expert settings can drastically affect the performance and access to the product. These settings should only be changed by an experienced network administrator. Figure 8-1.
8: Setup Mode: Advanced Settings ARP Cache timeout in seconds Whenever the unit communicates with another device on the network, it adds an entry into its ARP table. The ARP Cache timeout option allows you to define how many seconds (1-600) the unit will wait before timing out this table. The default setting is 600.
8: Setup Mode: Advanced Settings Security Settings (Option 6) You can change security settings by means of Telnet or serial connections only, not on the Web-Manager. We recommend that you set security over the dedicated network or over the serial setup to prevent eavesdropping. Caution: Disabling both Telnet Setup and Port 77FE will prevent users from accessing the setup menu from the network. Disabling Port 77FE also disables the Web from configuring the device. Select 7 to configure security settings.
8: Setup Mode: Advanced Settings Disable TFTP Firmware Update This setting defaults to the N (No) option. The Y (Yes) option disables the use of TFTP to perform network firmware upgrades. With this option, you can download firmware upgrades over the serial port using DeviceInstaller’s Recover Firmware procedure. (See 9: Firmware Upgrades.
8: Setup Mode: Advanced Settings Default Settings (Option 7) Select 7 to reset the unit’s Channel 1 configuration and expert settings to the default settings. The server configuration settings for IP address, gateway IP address, and netmask remain unchanged. The configurable pins’ settings also remain unchanged.
8: Setup Mode: Advanced Settings Disable Web Setup No Disable ECHO ports Yes Enable Enhanced Password No UDS1100 User Guide 59
9: Firmware Upgrades Obtaining Firmware You can obtain the most up-to-date firmware and release notes for the unit from the Lantronix web site (www.lantronix.com) or by using anonymous FTP (ftp.lantronix.com). Reloading Firmware There are several ways to update the unit's internal operational code (*.ROM): using DeviceInstaller (the preferred way), using TFTP, or using the serial port. You can also update the unit's internal Web interface (*.COB) using TFTP or DeviceInstaller.
9: Firmware Upgrades Figure 9-1. TFTP Window After the firmware has been loaded and stored, which takes approximately 8 seconds to complete, the unit performs a power reset. Using TFTP: Command Line Interface To download new firmware from a computer: 1. Enter the following from a TFTP command line interface: tftp –i put The following examples demonstrate the TFTP command sequence to download the .rom file and the .cob file: tftp –i 192.168.1.
9: Firmware Upgrades 5. For Firmware File, click the Browse button and go to the location where the firmware file resides. Note: Make sure the UDS1100 on which you are recovering firmware is connected to this selected port on your PC. 6. Click OK to download the file. 7. When prompted, reset the device. Status messages and a progress bar at the bottom of the screen show the progress of the file transfer. When the file transfer completes, the message “Successful, Click OK to Close” displays. 8.
10: Monitor Mode Monitor Mode is a command-line interface used for diagnostic purposes. There are two ways to enter Monitor Mode: locally using the serial port or remotely using the network. Entering Monitor Mode Using the Serial Port To enter Monitor Mode locally: 1. Follow the same steps used for setting the serial configuration parameters (see Serial Port on page 36). 2. Instead of typing three x keys, however: a) Type zzz (or xx1) to enter Monitor Mode with network connections.
10: Monitor Mode Table 10-1. Monitor Mode Commands Command Command Name Function VS x.x.x.x Version Queries software header record (16 bytes) of unit with IP address x.x.x.x. GC x.x.x.x Get Configuration Gets configuration of unit with IP address x.x.x.x as hex records (120 bytes). SC x.x.x.x Send Configuration Sets configuration of unit with IP address x.x.x.x from hex records. PI x.x.x.x Ping Pings unit with IP address x.x.x.x to check device status.
11: Troubleshooting and Contact Information This chapter discusses how you can diagnose and fix errors quickly without having to contact a dealer or Lantronix. It helps to connect a terminal to the serial port while diagnosing an error to view summary messages that may display. When troubleshooting, always ensure that the physical connections (power cable, network cable, and serial cable) are secure. Note: Some unexplained errors might be caused by duplicate IP addresses on the network.
11: Troubleshooting and Contact Information Problems and Error Messages Table 11-2. Problems and Error Messages Problem/Message Reason Solution When you issue the ARP –S command in Windows, the "ARP entry addition failed: 5" message displays. Your currently logged-in user does not have the correct rights to use this command on this PC. Have someone from your IT department log you in with sufficient rights.
11: Troubleshooting and Contact Information Problem/Message Reason Solution When you try to assign an IP with DeviceInstaller, you get the following : The cause is most likely one of the following: Double-check the parameters that you specified. The hardware address you specified is incorrect. Note: You cannot assign an IP address to a device server through a router. "No response from device! Verify the IP, Hardware Address and Network Class. Please try again.
11: Troubleshooting and Contact Information Problem/Message Reason Solution The device server appears to be set up correctly, but you are not communicating with your device attached to the device server across the network. If you are sure that the serial port setting is correct, then you may not be connecting to the correct socket of the device server. You can check to see whether there is a socket connection to or from the UDS by looking at the Status LED.
12: Connections and Pinouts Serial Port The UDS has a female DCE DB25 serial port that supports RS-232 and RS-485/422 serial standards (software selectable) up to 230 Kbaud. Figure 12-1. Serial Interface DB25 Serial Port Serial Connector Pinouts The unit’s female DB25 connector provides an RS-232C, RS-485, or RS-422 DCE serial port. The default serial port settings are 9600 baud, 8 bits, no parity, and 1 stop bit. Figure 12-2.
12: Connections and Pinouts Figure 12-3. DB25 Female Interface RS422 (4 wire mode) Figure 12-4. DB25 Female Interface RS485 (2 wire mode) Modem Cable When attaching the DB25 of the UDS to the DB9 com port on a PC, use a standard straight-through serial cable (Lantronix Part No. 500-163). The figure below shows the pinouts for a DB25 to DB9 straight-through cable, often referred to as a "Modem Cable". To configure the UDS using the DB9 serial port, you need only pin out the TXD, RXD, and GND signals.
12: Connections and Pinouts Figure 12-5. Null Modem Cable (Lantronix Part No. 500-163) Network Port The unit's back panel contains a power plug and an RJ45 (10/100) Ethernet port. Figure 12-6.
12: Connections and Pinouts Ethernet Connector Pinouts The UDS1100 supports 10/100 Mbps half or full duplex Ethernet through an RJ45 connector. Figure 12-7. RJ45 Ethernet Connector ug Power Plug Power input on the power plug is 9 -30 VDC (center +) or 10-24 VAC (1.5W maximum power required).
13: Technical Specifications Table 13-1.
13: Technical Specifications Category Description DeviceInstaller software System Software DeviceInstaller, Windows® 95/98/ME/NT/2000/XP-based configuration software Com Port Redirector, Windows® 98/NT/2000/XP-based virtual com port software LEDs Power 10/100 Mb Link 10/100 Activity Diagnostic Status Emissions FCC Part 15 Subpart B Class A Radiated Emissions 30MHz – 1000MHz ICES-003 Issue 4 February 2004 Class A Radiated Emissions 30MHz – 1000MHz AS/NZS CISPR 22: 2004 Class A Radiated Emissions 30MH
A: Alternative Ways to Assign an IP Address Earlier chapters describe how to assign a static IP address using DeviceInstaller, Web Manager, and Setup Mode (through a Telnet or serial connection). This section covers other methods for assigning an IP address over the network. DHCP The unit ships with a default IP address of 0.0.0.0, which automatically enables DHCP. If a DHCP server exists on the network, it provides the unit with an IP address, gateway address, and subnet mask when the unit boots up.
A: Alternative Ways to Assign an IP Address BOOTP Similar to DHCP, but for smaller networks. Automatically assigns the IP address for a specific duration of time. ARP and Telnet If the unit has no IP address, you can use Address Resolution Protocol (ARP) method from UNIX and Windows-based systems to assign a temporary IP address. To assign a temporary IP address: 1.
B: Binary to Hexadecimal Conversions Many of the unit’s configuration procedures require assembling a series of options (represented as bits) into a complete command (represented as a byte). Convert the resulting binary value to a hexadecimal representation. Converting Binary to Hexadecimal Following are two simple ways to convert binary numbers to hexadecimals. Conversion Table Hexadecimal digits have values ranging from 0 to F, which are represented as 0-9, A (for 10), B (for 11), etc.
B: Binary to Hexadecimal Conversions Scientific Calculator Another simple way to convert binary to hexadecimals is to use a scientific calculator, such as the one available on Windows’ operating systems. For example: 1. On the Windows’ Start menu, click ProgramsÆAccessoriesÆCalculator. 2. On the View menu, select Scientific. The scientific calculator displays. 3. Select Bin (Binary), and type the number to convert. 4. Click Hex. The hexadecimal value displays.
C: Warranty Lantronix warrants each Lantronix product to be free from defects in material and workmanship for a period of TWO YEARS after the date of shipment. During this period, if a customer is unable to resolve a product problem and Lantronix Technical Support determines the product is defective, a Return Material Authorization (RMA) will be issued. Following receipt of an RMA number, the customer shall return the product to Lantronix, freight prepaid.
D: Compliance and Disclaimer Manufacturer’s Name & Address Lantronix 15353 Barranca Parkway, Irvine, CA 92618 USA Declares that the following product: Product Name Model: UDS1100 Device Server Conforms to the following standards or other normative documents: Safety UL 60950-1 CSA 22.2.
D:Compliance and Disclaimer Disclaimer and Supplementary Information This product has been designed to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against such interference when operating in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy, and if not installed and used in accordance with this guide, may cause harmful interference to radio communications.
Index Applications, 9 ARP and Telnet, 76 AutoIP, 15, 75 Binary to hexadecimal conversions, 77 BOOTP, 15, 76 Channel settings, 27, 40 Command line interface, 35 Configuration methods, 11 Connect Mode, 42 Connection settings TCP, 29 UDP, 32 Connectors, 69 Contacts, 2 Default settings applying in Setup Mode, 58 applying in Web-Manager, 34 DeviceInstaller accessing the unit, 21 assigning the IP address, 16 installing from product CD, 16 DHCP, 15, 75 DHCP name.