Owners manual

8: Devices
SLCâ„¢ Console Manager User Guide 102
Console Port
The console port initially has the same defaults as the device ports. Use the Console Port page to
change the settings, if desired.
To set console port parameters:
1. Click the Devices tab and select Console Port. Figure 8-9 shows the page that displays.
Figure 8-9 Console Port Page
2. Enter the following fields.
Status
(view only)
Displays the status of the console port.
Baud Select the baud rate (speed) with which the device port exchanges data with the
attached serial device. Most devices use 9600 for the administration port, so the
console port defaults to this value.
Data Bits Select the number of data bits used to transmit a character. The default is 8 data
bits.
Stop Bits Select the number of stop bits that indicate that a byte of data has been transmitted.
The default is 1.
Parity Select the parity checking which detects simple, single-bit errors. The default is
none.
Flow Control Select a method of preventing buffer overflow and loss of data. The available
methods include none, xon/xoff (software), and RTS/CTS (hardware). The default is
none.
Timeout Click the No or Yes button. Input the number of minutes (1-30) if you clicked Yes
after which an idle session on the console is automatically logged out. Disabled by
default.