Owners manual

9: Administration
SGX 5150 IoT Device Gateway User Guide 80
Discovery
Network discovery allows your computer to locate other computers and devices on the network.
This setting also allows other computers to see your computer.
The current statistics and configuration options for device discovery, including UPnP query port,
are available for the SGX 5150 unit.
Table 9-5 Discovery Settings
To Configure Discovery
Using Web Manager
To configure Discovery, on the Administration page, click Discovery.
Using the CLI
To enter Discovery command level: enable > config > discovery
Using XML
Include in your file: <configgroup name="discovery">
Email
View and configure email alerts relating to events occurring within the system.
Table 9-6 Email Configuration
Discovery Settings Description
Query Port Server State Select to enable or disable the query port server from responding to
autodiscovery messages on port 0x77FE.
UPnP Server State Select to enable or disable the UPnP server from discovering devices in
Windows network places.
UPnP Server Port Update the UPnP server port. Leaving this field blank will restore the default
settings.
Email – Configuration
Settings
Description
From Click the Configure SMTP link to configure SMTP. See SMTP (on page 98).
To Enter the email address to which the email alerts will be sent. Multiple addresses
are separated by semicolon (;). Required field if email is to be sent.
CC Enter the email address to which the email alerts will be copied. Multiple addresses
are separated by semicolon (;).
Reply To Enter the email address to list in the Reply-To field of the email alert.
Subject Enter the subject for the email alert.
Note: Emails sent as a result of an alarm will display the name of the alarm in the
subject of the email, overriding the email subject configured in this field.
Message File Enter the path of the file to send with the email alert. This file appears within the
message body of the email, not as an attachment.