Owners manual

6: Network Settings
SGX 5150 IoT Device Gateway User Guide 47
To View and Configure Wired Network QoS Settings
Using Web Manager
To view Ethernet (eth0) QoS statistics, click Network on the menu and select
Wired Network > QoS.
To modify Ethernet (eth0) QoS information, click Network on the menu and select
Wired Network > QoS > Configuration.
Using the CLI
To enter the eth0 QoS command level: enable > config > if 1 > qos
Using XML
Include in your file: <configgroup name="ethernet" instance="eth0">
Wired (eth0) Network Failover
The SGX 5150 device gateway provides WAN network failover, in the form of a "dead remote host
reachability" mechanism (essentially a ping against a known host). If the remote host is
determined to be not reachable, the device will failover to the Wi-Fi interface. If the remote host is
determined to be reachable, the device will failback to the Ethernet interface.
Table 6-6 Wired (eth0) Network Failover Settings
Network Enter the Network, if the Network filter type is selected.
Ports Enter the Port, if the Port filter type is selected.
Priority Select the priority of the filter from the drop-down menu.
Wired Network
(Failover) Settings
Description
State Click to enable or disable state.
Failover Interface Always select wlan0 in the SGX 5150 device gateway.
Hostname Enter the remote host to test reachability.
Ping Protocol Select ICMP or TCP based ping.
Timeout Indicate the interval to wait for ping response from remote host.
Interval Indicate the interval in which to test reachability
Failover Threshold Indicate the allowed number of failed pings – after which the device will failover to
the wlan0 interface.
Failback Threshold Indicate the number of successful pings – after which the device will failback to the
Ethernet interface.
Wired (eth0) Network
Settings
Description