User Manual

Command Reference Server Commands
12-116
Delay
Schedules the initialization to take place after a specified number of minutes.
Must be used in conjunction with the delay parameter.
delay
An integer between zero and 120, representing seconds before the
initialization. Zero specifies an immediate reboot.
Note: Show/Monitor/List Server will display the time remaining before a scheduled
initialization.
Factory
Reloads the factory settings. All configurations made with the Define and Save
commands will be cleared and will have to be reconfigured.
Noboot
Forces the SCS to remain in the Boot Configuration Program (BCP) instead of
booting.
Reload
On Flash ROM equipped units, re-downloads the operational code and
reprograms the Flash ROM.
Examples
Local>> INITIALIZE DELAY 2
Local>> INITIALIZE RELOAD FACTORY DELAY 12
Local>> INITIALIZE FACTORY
Local>> INITIALIZE CANCEL
See Also Rebooting, page 2-5; Reloading Operational Software, page 2-6
12.9.3 Set/Define Menu
Configures individual Menu Mode menu choices and the menus title banner. You can also configure the
menus using a preconfigured text file, which is specified using the filename parameter and is normally saved
on the flash disk .
When using a configuration file, use the Set Menu command to parse the file before using Define to commit
the file into use.
Note: You should add a menu entry that allows users to log out. This can be
accomplished by adding a “Logout Port Port” command to the end of the menu.
Restrictions Requires privileged user status.
Errors The Define command only works with the File parameter if the file is saved in
/flash.
SET
DEFINE



MENU
ItemNum String Command
TITLE TitleString
FILE filename




