User Manual
Command Reference Port Commands
12-84
12.6.51 Set Privileged/Noprivileged
Changes the current port’s privilege status. Only one port on the server can be privileged at any time. The
Override parameter is provided to force your current port to become the privileged port (and the previously
privileged port loses the privilege).
When changing your port to privileged status, you will be queried for the privileged password. The factory
default privileged password is system; this password can be changed with the Set Server Privileged
Password command. If the password is forgotten, the server can be reset to factory defaults using the
Initialize commands.
Restrictions To use the Privileged parameter, you must know the privileged password.
Secure users cannot become privileged.
Examples
Local>> SET NOPRIVILEGED
Local>> SET PRIVILEGED OVERRIDE
See Also Set/Define Ports Security, page 12-76; Privileged Password, page 2-6
12.6.52 Define Protocols RS485
Enables RS-485 networking and configures the necessary RS-485 parameters on the SCS200.
Restrictions Requires privileged user status.
Errors Only applies to the SCS200.
In two-wire mode, TXDrive must be set to Auto.
SET
PRIVILEGED
OVERRIDE
NOPRIVILEGED
DEFINE PROTOCOLS RS485
DISABLED
ENABLED
MODE
2WIRE
4WIRE
TERMINATION
ENABLED
DISABLED
TXDRIVE
ALWAYS
AUTO