User's Manual
Table Of Contents
- PremierWave XC HSPA+ User Guide
- 1: Using This Guide
- 2: Introduction
- 3: Installation of PremierWave XC HSPA+
- 4: Using DeviceInstaller
- 5: Configuration Using Web Manager
- 6: Network Settings
- Network 1 (eth0) Interface Settings
- Network 1 (Link) Settings
- Network 1 (Failover)
- Network 2 (Cellular) Settings
- Network 2 (Link) Settings
- Gateway
- 7: Cellular
- 8: Action Settings
- 9: Line and Tunnel Settings
- Line Settings
- Tunnel Settings
- Serial Settings
- To Configure Tunnel Serial Settings
- Packing Mode
- To Configure Tunnel Packing Mode Settings
- Accept Mode
- To Configure Tunnel Accept Mode Settings
- Connect Mode
- To Configure Tunnel Connect Mode Settings
- Disconnect Mode
- To Configure Tunnel Disconnect Mode Settings
- Modem Emulation
- To Configure Tunnel Modem Emulation Settings
- Relay Output
- 10: Terminal and Host Settings
- 11: Services Settings
- 12: Security Settings
- 13: Maintenance and Diagnostics Settings
- Filesystem Settings
- Protocol Stack Settings
- SMTP Settings
- Diagnostics
- Threads
- Clock
- System Settings
- Discovery and Query Port
- 14: Advanced Settings
- 15: Security in Detail
- 16: Updating Firmware
- 17: Branding the PremierWave XC HSPA+
- Appendix A: Technical Specifications
- Appendix B: Compliance
- Appendix C: Technical Support
- Appendix D: Binary to Hexadecimal Conversions
- Appendix E: USB-CDC-ACM Device Driver File for Windows Hosts
PremierWave XC HSPA+ User Guide 42
8: Action Settings
Actions can be configured for alarms and reports available in the PremierWave.
Alarms and Reports
PremierWave XC HSPA+ updates the action settings page to display and configure the alarms.
The following alarm and report acations are available in PremierWave XC HSPA+:
Eth0 Link State Change
Wwan0 Link State Change
Digital Input 1 State Change
Digital Input 2 State Change
One or more types of “action” can be configured and triggered when an event occurs.
Actions
Table 8-1 contain the configuration options for all the alarms and reports listed above.
Table 8-1 Action Settings
Action Settings Description
Delay Use Delay to defer alarm processing. Alarm actions will not be executed if the cause
is corrected within this time.
Email Use Email to send an email to configured Email recipients. If an Alarm Email profile
number is selected, that email will be sent when the alarm is turned on. The contents
of Alarm Message will be placed into the email body when an alarm email is sent. If
the alarm stays on longer than the Reminder Interval, another alarm email is sent. If
a Normal Email profile number is selected, that email will be sent when the alarm is
turned off. The contents of Normal Message will be placed into the email body when
a normal email is sent. If the alarm stays off longer than the Reminder Interval,
another normal email is sent.
FTP Put Use FTP Put to put a file on configured FTP server. Filename will be used to upload
to remote FTP server. The IP Address or hostname is the FTP server to connect to.
Port number is port on which FTP server is listening on. Use Protocol to connect to
FTP server. FTPS is a SSL encrypted communication channel and SSL Trusted
Authorities must be setup with FTP server SSL certificate. Username is used to
logon to FTP server. If FTP server does not require authentication, use anonymous.
Password is used to logon to FTP server. If FTP server does not require
authentication, a common practice is to use user’s email address. If the alarm stays
on or off longer than the Reminder Interval, another FTP Put is performed. In
Sequential mode, connections will be attempted starting with number 1 until a
connection is successful. In Simultaneous mode, all possible connections will be
made.
PRELIMINARY DRAFT
PRELIMINARY DRAFT