In Accept Mode, the PremierWave XC listens (waits) for incoming connections from the network.
A remove node on the network initiates the connection.
The configurable local port is the port the remote device connects to for this connection. There is
no remote port or address. The default local port is 10001 for serial line 1 and 10002 for serial
line 2.
Serial data can still be received while waiting for a network connection, keeping in mind serial
data buffer limitations.
Table 7-5 Tunnel Accept Mode Settings
Tunnel Accept Mode
Settings
Description
Mode Sets the method used to start a tunnel in Accept mode. Choices are:
Disable = do not accept an incoming connection.
Always = accept an incoming connection. (default)
Any Character = start waiting for an incoming connection when any
character is read on the serial line.
Start Character = start waiting for an incoming connection when the
start character for the selected tunnel is read on the serial line.
Modem Control Asserted = start waiting for an incoming connection as
long as the Modem Control pin (DSR) is asserted on the serial line until
a connection is made.
Modem Emulation = start waiting for an incoming connection when
triggered by modem emulation AT commands. Connect mode must also
be set to Modem Emulation.
Local Port Sets the port number for use as the network local port. The defaults are as
follows:
Tunnel 1 : 10001
Tunnel 2 : 10002
Protocol Select the protocol type for use with Accept Mode:
SSH
SSL
TCP (default protocol)
TCP AES
Telnet
TCP Keep Alive Enter the time, in milliseconds, the PremierWave XC waits during a silent
connection before checking if the currently connected network device is still
on the network. If the unit then gets no response after 8 attempt, it drops
the connection. Enter 0 to disable.
Flush Serial Sets whether the serial Line data buffer is flushed upon a new network
connection. Choices are:
Enabled = serial data buffer is flushed on network connection
Disabled = serial data buffer is not flushed on network connection
(default)
PremierWave XC User Guide 50