5: Line and Tunnel Settings
PremierWave EN User Guide 33
Line Settings
Description
Mode, a CLI session operates exclusively on the Line. Choices are:
Disable
Always
Note: In order to enable command mode on the Line, Tunneling on
the Line must be Disabled (both connect and accept modes).
Table 5-1 Using the CLI to Configure Line Settings
To enter Line 1 level
enable->line 1
Table 5-2 Using XML to Configure Line Settings
For Line 1
configgroup name = "line" instance = "1"
For Line 1 Command Mode
configgroup name = "serial command mode" instance = "1"
Tunnel Settings
The Tunnel Settings allow you to configure how the Serial-Network tunneling operates.
Tunneling is available on all serial Lines.
Accept Mode
In Accept Mode, the PremierWave EN listens (waits) for incoming connections from the
network. Serial data can still be received while waiting for a network connection, keeping in
mind serial data buffer limitations.
Tunnel Accept Mode
Settings
Description
Accept Mode
Sets the method used to start a tunnel in Accept mode. Choices are:
Disable = do not accept an incoming connection.
Always = accept an incoming connection. (default)
Local Port
Sets the port number for use as the network local port. The defaults
are as follows:
Tunnel 1 : 10001
Tunnel 2 : 10002
Tunnel 3 : 10003
Protocol
Sets the protocol type for use with Accept Mode. Choices are:
TCP
= Use TCP protocol for network connection. (default)
Flush Serial
Sets whether the serial Line data buffer is flushed upon a new network
connection. Choices are:
Enable = serial data buffer is flushed on network connection
Disable = serial data buffer is not flushed on network connection
(default)