User Manual

Table Of Contents
5: Line and Tunnel Settings
PremierWave EN User Guide 32
Line Settings
The Line Settings allow configuration of the serial Lines (ports).
Some settings may be specific to only certain Lines. Such settings are noted below.
Line Settings
Description
Name
Enter a name or short description for the line, if desired. By default,
there is no name specified. A name that contains whitespace must
be quoted.
Interface
Sets the interface type for the Line. The default is RS232 for Lines 1
and 2, and USB-CDC-ACM for Line 3.
Choices are:
RS232 (Lines 1 and 2 only)
RS485 Full-Duplex (Lines 1 and 2 only)
RS485 Half-Duplex (Lines 1 and 2 only)
USB-CDC-ACM (Line 3 only) = CDC-ACM over USB
Termination
Sets the Line Termination to Enable or Disable. The default is
Disable.
Note: This setting is only relevant for Lines 1 and 2 with Interface
type RS485 Half-Duplex.
State
Sets the operational state of the Line to either Enable or Disable.
The default is Enable.
Protocol
Sets the operational protocol for the Line. The default is Tunnel.
Choices are:
None
Tunnel = Serial-Network tunneling protocol.
Baud Rate Sets the Baud Rate (speed) of the Line. The default is 9600.
Any speed between 300 and 921600 may be selected, but the
following standard rates are recommended:
300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200,
230400, 460800, 921600.
Note: For Interface type USB-CDC-ACM (Line 3 only), this setting is
irrelevant.
Parity
Sets the Parity of the Line. The default is None.
Note: For Interface type USB-CDC-ACM (Line 3 only), this setting is
irrelevant.
Data Bits
Sets the number of data bits for the Line. The default is 8.
Note: For Interface type USB-CDC-ACM (Line 3 only), this setting is
irrelevant.
Stop Bits
Sets the number of stop bits for the Line. The default is 1.
Note: For Interface type USB-CDC-ACM (Line 3 only), this setting is
irrelevant.
Flow Control
Sets the flow control for the Line. The default is None.
Note: For Interface type USB-CDC-ACM (Line 3 only), this setting is
irrelevant.
Command Mode
Sets the Command Mode state of the Line. When in Command