User's Manual
Table Of Contents
MatchPort b/g™ User Guide 68
7
7
:
:
M
M
o
o
n
n
i
i
t
t
o
o
r
r
M
M
o
o
d
d
e
e
Monitor Mode is a command-line interface used for diagnostic purposes.
There are two ways to enter Monitor Mode: locally using the serial port or remotely
via the network.
Note: The MatchPort b/g is based on a standard release of Lantronix's CoBos
operating system. Some CoBos products support both wired and wireless
interfaces. The MatchPort b/g currently supports only wireless. Please ignore
references and settings that deal with a wired Ethernet interface.
Entering Monitor Mode via the Serial Port
To enter Monitor Mode locally:
1. Follow the same steps used for setting the serial configuration parameters (see
Serial Port Access on page 36).
2. Instead of typing three x keys, however:
a) Type zzz to enter Monitor Mode with network connections.
b) Type yyy to enter Monitor Mode without network connections.
A 0> prompt indicates that you have successfully entered Monitor Mode.
Entering Monitor Mode via the Network Port
To enter Monitor Mode using a Telnet connection:
1. Establish a Telnet session to the configuration port (9999).
2. When the Press Enter to go into Setup Mode prompt displays, type M (upper
case).
A 0> prompt indicates that you have successfully entered Monitor Mode.
Monitor Mode Commands
The following commands are available in Monitor Mode.
Note: All commands must be in capital letters.
Table 7-1. Monitor Mode Commands
Command Command Name Function
VS
Version Queries software header record (16 bytes) of unit.
GC
Get Configuration
Gets configuration of unit as hex records (120
bytes).
SC
Send Configuration Sets configuration of unit from hex records.