User's Manual
Table Of Contents
5: Configuration via Serial Mode or Telnet Port
MatchPort b/g™ User Guide 42
Connect Mode
Connect Mode defines the unit’s connection method and its reaction to incoming
connections over the network. The current value displays in parentheses.
ConnectMode (C0) ? _
Enter Connect Mode options in hexadecimal notation:
Note: All bit positions in the table that are blank represent “don’t care” bits for
that particular option, which can be set to either a 0 or 1 value.
Table 5-7. Connect Mode Options
Connect Mode Option 7 6 5 4 3 2 1 0
a) Incoming Connection
Never accept incoming 0 0 0
Accept with Modem Control In Active 0 1 0
Always Accept 1 1 0
b) Response
Nothing (quiet) 0
Character response (C=connect,
D=disconnect, N=unreachable)
1
c) Active Startup
No active startup 0 0 0 0
With any character 0 0 0 1
With Modem Control In Active 0 0 1 0
With a specific start character 0 0 1 1
Manual connection 0 1 0 0
Autostart 0 1 0 1
Hostlist 0 0 1 0
d) Datagram Type
Directed UDP 1 1 0 0
e) Modem Mode
No Echo 0 0 1 1
Echo & Modem Response (Numeric) 0 1 1 1 1
Echo & Modem Response (Verbose) 0 1 1 1 0
Modem Response Only (Numeric) 0 0 1 1 1 1
Modem Response Only (Verbose) 0 0 1 1 1 0