User's Manual
Table Of Contents
4: Configuration Using Web-Manager
MatchPort b/g™ User Guide 34
Direction
Select whether the pin inputs or outputs.
Trigger Input Select whether the GPIO input signal is to be used as a trigger
condition for email.
Active Level Select the signal active level (Low or High).
Configurable Pin Functions
General Purpose I/O
Monitors input or controls output by means of the 77F0 port.
Modem Ctrl Channel 1 In Allows for control of the connection (and disconnection) of
channel 1.
Modem Ctrl Channel 1
Out
Indicates a connection is established on channel 1.
Serial Channel 1 Status
LED
Indicates channel 1 status and extended diagnostics when the
Diagnostics LED is lit.
Reset to Defaults
(Wireless)
Asserting during bootup for at least 7 seconds resets the
configuration back to factory defaults. Used when network
access is impossible because of improper configuration.
RS-485 Select out
Selects between RS-232 and RS-485 line drivers.
RS-485 2 Wire out Selects 2-wire line drivers. Usable as a half/full duplex
selector.
RS-422/485 4 Wire out
Selects 4-wire line drivers
Reset to Defaults
(Ethernet)
Asserting during bootup for at least 7 seconds resets the
configuration back to factory default. Used when network
access is impossible because of improper configuration.
Updating Settings
Click the Apply Settings button from the main menu to save and apply the
configuration changes.
Applying Defaults
Click the Apply Defaults button from the main menu to apply the factory settings to
the MatchPort. For a list of the default settings, see Default Settings on page 61.