User Manual

Set/Define Service Commands Command Reference
12-86
12.47.4 Set/Define Service Binary
If the binary characteristic is enabled on a service, there will be no data processing (<CR> to <CR><LF>
translation and tab expansion). The binary characteristic should be enabled when printing PCL data.
Applies To EPS4, ETS4P, ETS8, ETS8P, ETS16, ETS16P
Restrictions You must be the privileged user to use this command.
See Also Clear/Purge Service, page 12-7; Show/Monitor/List Services, page 12-111;
TCP/Telnet Service Sockets, page 4-14.
12.47.5 Set/Define Service DLC
Specifies that the service will handle DLC print requests from Windows NT hosts. Note that only one
service on the ETS can have DLC enabled at any time.
Applies To EPS4, ETS4P, ETS8, ETS8P, ETS16, ETS16P
Restrictions You must be the privileged user to use this command.
See Also Clear/Purge Service, page 12-7; Show/Monitor/List Services, page 12-111;
TCP/Telnet Service Sockets, page 4-14; DLC, page 11-1.
12.47.6 Set/Define Service EOJ
Specifies a string to be sent to the attached device at the end of every job regardless of network protocol.
Applies To EPS4, ETS4P, ETS8, ETS8P, ETS16, ETS16P
Restrictions You must be the privileged user to use this command.
SET
DEFINE



SERVICE ServiceName BINARY
ENABLED
DISABLED



SET
DEFINE



SERVICE ServiceName DLC
ENABLED
DISABLED



SET
DEFINE



SERVICE ServiceName EOJ
EndString
NONE


