Set/Define Port Commands Command Reference
12-52
Applies To EPS4, ETS4P, ETS8, ETS8P, ETS16, ETS16P
Restrictions You must be the privileged user to use this command.
Parameters PortList/All
Specifies a particular port or group of ports, or all ports. Port numbers are
specified with integers between 1 and the total number of physical ports. Lists
of ports must be separated by commas. Ranges of ports must be separated by
a dash (-).
Note: In the absence of a PortList or the All parameter, the configuration will affect the
current port only.
baudrate
Acceptable baud rates include 300, 600, 1200, 2400, 4800, 9600, 19200,
38400, 57600, and 115200, and 230400 (Fast Ethernet print servers only).
Examples
Local> DEFINE PORT 7-8 SPEED 9600
See Also Set/Define Port Autobaud, page 12-28; Show/Monitor/List Ports, page 12-102;
Baud Rate, page 5-2.
12.43.38 Set/Define Port Stop
Configures whether the port will use one or two stop bits. The default is to use one stop bit.
Applies To EPS4, ETS4P, ETS8, ETS8P, ETS16, ETS16P
Restrictions You must be the privileged user to use this command.
Parameters PortList/All
Specifies a particular port or group of ports, or all ports. Port numbers are
specified with integers between 1 and the total number of physical ports. Lists
of ports must be separated by commas. Ranges of ports must be separated by
a dash (-).
Note: In the absence of a PortList or the All parameter, the configuration will affect the
current port only.
See Also Set/Define Port Parity, page 12-44; Set/Define Port Character Size, page 12-
33; Show/Monitor/List Ports, page 12-102; Parity, Character Size, and Stop
Bits, page 5-4.
SET
DEFINE



PORT
PortList
ALL
STOP
1
2


