Installation Guide
5
CWE 6060 Remote Installation Guide 98-1551 19
Troubleshooting
What if the register is not compatible with the CWE?
Verify that the register is one of the following:
•Badger ADE
®
• Neptune ProRead (ARB VI)
• Sensus ECR-II
• Sensus ECR-III
• AMCO Scancoder
If the register is not one of the models listed above, replace with a supported register type and/or the
appropriate meter.
What if the RF Buster does not beep when testing the installation?
Does the RF Buster beep and light the LED when the switch is initially pressed? if not, the battery in
the RF Buster is dead. Replace the RF Buster battery, or use another RF Buster.
Be careful not to hold the RF Buster magnet near the CWE magnet sensor on the right of the
enclosure for more than 1 second.
After activating the magnetic switch on the CWE, hold the RF Buster switch on continuously. Point
the LED end of the RF Buster toward the front of the CWE. Hold the RF Buster between 6” and 12”
from the front of the CWE. Wait 10 seconds. If the RF Buster does not beep, replace the CWE.
What if the RF Buster does not beep more than 6 times when testing the
installation?
For Neptune registers, if the register is labeled “Pro”, double-check that it is configured for 3-wire
mode as instructed on "Reprogramming a ProRead encoder from 2-wire to 3-wire" on page -13. Re-
check the manufacturer and model of the register that you are installing. Make sure you have used
the correct color code for that register.
Check the wire between the CWE and the register for cuts, nicks, or broken wires. Repair or replace
the cable if necessary.
If you are using a Pro-read encoder, make sure it is programmed for 3-wire mode.
If the CWE still does not transmit more than 6 times, replace it.