Chapter 2 - Installing the Cellnet Water Endpoint Landis+Gyr
8 98-1552 CWE 6060 Remote Installation Guide
If the register has potted leads, proceed to "Connecting a Badger, Neptune Auto, Sensus Encoder,
or AMCO Scancoder Register with Potted Leads" on page -11
"UPro-Read Encoder Register" on page -13
Connecting a Neptune Auto, Sensus Encoder, or AMCO Scancoder
Register with Screw Terminals
Remove terminal cover. Use clean, disposable towels or rags to wipe the gel away from the terminals
and screws. After the gel is removed, disconnect any wires connected to the terminals. Clean the
terminals and screws again using Dow Corning OS-2 Silicone Cleaner or equivalent. Be careful not
to lose any screws when disconnecting the wires or cleaning the screw terminals.
If the cable to be connected to the screw terminals has been pre-stripped, proceed to step 3 below.
1Usingthe#10AWGposition(secondlargesthole)onthe641919wirestripper,remove1.5
inchesofexternalinsulationfromthecable.
Figure 2 - 1. 64-1919 Wire stripper
Do not damage the internal wire insulation when removing the external insulation.