Certification Exhibit FCC ID: R7PER0R1S2 IC: 5294A-ER0R1S2 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-210 ACS Report Number: 08-0302-15C Manufacturer: Cellnet Technology, Inc. Model: CWE WALL 2G Installation Guide 5015 B.U.
Cellnet Water Endpoint 6060 Remote Installation Guide 98-1552
Limitation on Warranties and Liability Information in this document is subject to change without notice. This manual or any part of it thereof may not be reproduced in any form unless permitted by contract or by written permission of Landis+Gyr.
Table of Contents Chapter 1: Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Chapter 2: Installing the Cellnet Water Endpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Chapter 3: Testing the Endpoint . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Chapter 4: Endpoint Replacement . . . . . . . . . . . . . . . . .
Landis+Gyr ii 98-1552 CWE 6060 Remote Installation Guide
1 Introduction This manual explains how to correctly install Cellnet Water Endpoints (CWE) for remote applications. It covers endpoint installation, encoder register connection, and troubleshooting. Tools and Equipment This section outlines the necessary tools and equipment for installing a Cellnet Water Endpoint for remote applications. Equipment The following table contains all required equipment: Table 1-1.
Chapter 1 - Introduction Image Landis+Gyr Description _~ÇÖÉê=cáÉäÇ=péäáÅÉ=háí=SOMUQJMMN Splice Enclosure Tie wraps 3M Scotchloks, Model UY2 or Equivalent açï=`çêåáåÖ=Q=bäÉÅíêáÅ~ä=fåëìä~íáåÖ=`çãéçìåÇ=Eçê=Éèìáî~äÉåíF jpap=~î~áä~ÄäÉ=~í=ïïïKÇçïÅçêåáåÖKÅçãK açï=`çêåáåÖ=lpJO=ëáäáÅçåÉ=`äÉ~åÉê=Eçê=Éèìáî~äÉåíF jpap=~î~áä~ÄäÉ=~í=ïïïKÇçïÅçêåáåÖKÅçãK mfkJfkJqlou oÉèìáêÉë=~=qlou=ÇêáîÉê=ëáòÉ=qNM=ïáíÜ=~=ÜçäÉ=Ñçê=íÜÉ=mfk ^ÇÇáíáçå~ä=Å~ÄäÉ péÉÅáÑáÅ~íáçåW=OOJ^td=pçäáÇ=`çééÉê `çäçêëW=oÉÇLdêÉÉåL_ä~Åâ ms`=g~ÅâÉí 2 98-1552
Landis+Gyr Chapter 1 - Introduction Tools The following table contains all required tools: Table 1-2.
Chapter 1 - Introduction Image Landis+Gyr Description kÉéíìåÉ=mêçoÉ~Ç=cáÉäÇ=mêçÖê~ããÉê=Eåçí=êÉèìáêÉÇ=Ñçê=^ìíç=çê= ^o_=S=ÉåÅçÇÉêëF ïïïKåÉéíìåÉíÖKÅçã Safety and Environment Prerequisite Training Installers should be instructed in the following safety elements as well as any site-specific safety issues: • Hazard Communication (Employee Right to Know) • Lifting • Safe driving • Use of hand tools • Confined space Preliminary Checks The installer should already be able to operate the HandHeld compute
Landis+Gyr Chapter 1 - Introduction FCC & Industry Canada Information to the User FCC Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
Chapter 1 - Introduction Landis+Gyr FCC ID: R7PER0R1S2 This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. IC: 5294A-ER0R1S2 This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
2 Installing the Cellnet Water Endpoint Locating the CWE The CWE Remote should be mounted above ground. If there is an existing touchpad or remote, then put the new remote in that location. It is preferred to mount the CWE outdoors, to a wall facing the nearest concentrator. Mounting the CWE Mounting techniques vary widely, depending on the physical characteristics of the customer site. The mounting technique used is left to the installer’s best judgement and experience.
Chapter 2 - Installing the Cellnet Water Endpoint Landis+Gyr • If the register has potted leads, proceed to "Connecting a Badger, Neptune Auto, Sensus Encoder, or AMCO Scancoder Register with Potted Leads" on page -11 • "UPro-Read Encoder Register" on page -13 Connecting a Neptune Auto, Sensus Encoder, or AMCO Scancoder Register with Screw Terminals Remove terminal cover. Use clean, disposable towels or rags to wipe the gel away from the terminals and screws.
Landis+Gyr Chapter 2 - Installing the Cellnet Water Endpoint 2 Using the #22 AWG hole of the wire‐stripping tool, strip one‐half inch of insulation from each of the three internal wires. Figure 2 - 2. Wire stripper 3 Connect the three‐conductor wire to the encoder registerʹs terminals, matching colors carefully. Thread the cable around the strain relief posts of the encoder register. Figure 2 - 3.
Chapter 2 - Installing the Cellnet Water Endpoint Landis+Gyr 10 Match the colors carefully using the following table Table 1 Color Matching Encoder Register 6060 Wire Color/Encoder Terminal kÉéíìåÉ=mêçoÉ~Ç=E^o_=sfF Blk/Green Green/R Red/B pÉåëìë=b`oJffI=b`oJfff=Ef`bF Blk/Blk Green/G Red/R ^j`l=pÅ~åÅçÇÉê Blk/Blk Green/G Red/R . All color translations will be done at the CWE Remote. If using existing wire, verify that no color translations are present.
Landis+Gyr Chapter 2 - Installing the Cellnet Water Endpoint Connecting a Badger, Neptune Auto, Sensus Encoder, or AMCO Scancoder Register with Potted Leads Use the following installation procedure for sites equipped with potted encoders. Do not open a potted encoder for any reason. This will void the manufacturer’s warranty. 1 Route the cable from the potted register to the CWE mounting location. Splice in additional cable as necessary.
Chapter 2 - Installing the Cellnet Water Endpoint 3 Landis+Gyr Splice the wires from the CWE to the encoder wires. Match colors carefully according to the table below: Table 2-1.
Landis+Gyr Chapter 2 - Installing the Cellnet Water Endpoint UPro-Read Encoder Register Before removing the ProRead receptacle, ensure that the ProRead register is programmed for threewire mode. • If a two-wire conductor cable is connected to a “potted” ProRead encoder register, replace the register with a three-wire register. Reprogramming a ProRead encoder from 2-wire to 3-wire It may sometimes be necessary to reprogram a ProRead register encoder from 2-wire to 3-wire mode.
Installing the Cellnet Water Endpoint Notes: 14 CWE 6060 Remote Installation Guide
3 Testing the Endpoint After you have completed the installation process, test the installation by passing an RF Buster magnet near the endpoint’s sensor. The CWE tests the connection to the register and transmits a pattern to indicate if the installation is good or bad. The RF Buster detects the transmission pattern, beeps and lights the LED. 1 Activate the CWE by passing the RF Buster magnet against the side of the CWE housing as the arrow indicates. RF Buster magnet Figure 3 - 1.
Testing the Endpoint Notes: 16 CWE 6060 Remote Installation Guide
4 Endpoint Replacement Use the HandHeld and Cellnet Remote Water Endpoint Programming Cable to deactivate all CWEs prior to leaving the worksite. The handheld prompts you to deactivate while processing the work order. 1 Open the face of the CWE Remote. 2 Write down the color translation. 3 Carefully cut any tie wraps. 4 Cut off Scotchloks near the crimp. 5 Unmount the CWE Remote. Refer to "Identifying the Register for Installation" on page -7.
Endpoint Replacement Notes: 18 CWE 6060 Remote Installation Guide
5 Troubleshooting What if the register is not compatible with the CWE? Verify that the register is one of the following: • Badger ADE® • Neptune ProRead (ARB VI) • Sensus ECR-II • Sensus ECR-III • AMCO Scancoder If the register is not one of the models listed above, replace with a supported register type and/or the appropriate meter.
Chapter 5 - Troubleshooting Landis+Gyr How can I tell the difference between a Sensus ECR-I and ECR-II encoder register? The easiest way to determine the difference between ECRI and ECRII is physical appearance. ECRI is a “high top” design with odometer wheels behind a a flange. If you still cannot determine which encoder register it is, please contact your local Sensus Meter Representative. Customer Support To reach Customer Support at Landis+Gyr: Email: solutionsupport.na@landisgyr.
A Crimping Wires Use this process to crimp wires for the Cellnet Water Endpoint. Crimping Wires 1 Strip the wires that are to be connected and push the stripped wires into the Scotchlok connector as far as possible. Figure A - 1. Stripped wires pushed into Scotchlok connector 2 Place the Scotchlok connector (with wires) into the jaws of the crimping tool. Figure A - 2. ScotchLok connector in crimping tool jaws Always use 3M Parallel Jaw Crimping Tool 3M Model E-9Y or equivalent.
Appendix A - Crimping Wires 3 Landis+Gyr Crimp the Scotchlok connector by squeezing the crimping tool handles until it discharges gel. Continue to apply pressure for no less than three seconds. Figure A - 3. Crimped Scotchloks discharge gel 4 Install the two plastic cable ties on the jackets of the spliced wires and tighten the cable ties securely for strain relief. Remove excess cable tie with wire cutters. Figure A - 4.
Landis+Gyr Appendix A - Crimping Wires 5 For splice connections outside the CWE Remote enclosure, insert the entire splice assembly into the silicone‐filled splice enclosure. Close the cover and position the leads to exit alternate sides Figure A - 5. Inserting splice assembly into silicone-filled splice enclosure Cellnet strongly recommends a splice enclosure. Failure to use a splice enclosure may invalidate the manufacturer’s warranty. The 3M Gel splice connector is NOT reusable.
Crimping Wires Notes: 24 CWE 6060 Remote Installation Guide
Glossary ADE Absolute Digital Encoder Concentrator Collects all information provided by the Cellnet endpoints. CWE Cellnet Water Endpoint CWE 6060 Remote Cellnet manufactured water endpoint (CWE) - available for remote, above-ground installation MIU Meter Interface Unit Potted terminal Terminal with integrated, water submersible, reusable connector PowerLAN Unique endpoint addresses Register Device used for registering water usage.
Glossary Notes: 26 CWE 6060 Remote Installation Guide
Index E bèìáéãÉåí NJN P mêçoÉ~Ç=cáÉäÇ=mêçÖê~ããÉê NJQ R oc=_ìëíÉê NJP S pÅçíÅÜäçâ∆=`êáãéáåÖ=qççä pÅêÉïÇêáîÉêë NJP píêáééÉê NJP NJP T qççäë NJP W táêÉ=`ìííÉê NJP CWE 6060 Remote Installation Guide 98-1551 27
Index 28 Landis+Gyr 98-1551 CWE 6060 Remote Installation Guide
Reader’s Comment Form Cellnet Water Endpoint 6060 Remote Installation Guide (98‐1552) Please use this form only to identify publication errors or to request changes in publications. Your comments assist us in improving our publications. Direct any requests for additional publications, technical questions about systems, changes in support, and so on, to your Landis+Gyr sales representative.
cçäÇ=eÉêÉ Landis+Gyr Attn.: Technical Documentation 30000 Mill Creek Ave.