User Manual

Landis+Gyr Endpoint Quick Start Guide
Quick Start Guide 98-2412 Rev AA 9
Gridstream RF G5 FOCUS AXe Specifications
Table 1. Specifications
Category Specification Value or Range
Compatible
Meters
Landis+Gyr FOCUS AXe
Supported Meter Forms
FOCUS AXe FOCUS AXe-SD
Form Class Form Class
1S-120V 100 1S 200
1S-240V 200 2S 200
2S 200
2SE 320
3S-120V 10/20
3S-240V 10/20
3SC-120V 10/20
3SC-240V 10/20
4S 10/20
Electrical
Voltage 11.4 V-12.6 V DC (from the meter's power supply)
Power Max: 4 W; Typical: 0.5W
RF 900 MHz RF
Output Power +27 dBm Typical
Adjacent Channel Power 40 dBc Typical (9.6 kbps)
Transmit Frequency 902.2 to 927.8 MHz ISM unlicensed (FCC Part 15)
Receive Sensitivity
-114 dBm Typical (9.6 kbps)
-105 dBm Typical (115.2 kbps)
-99 dBm Typical (300 kbps)
RF Baud Rates Supported 9.6, 19.2, 38.4, 50, 115.2, 150, 200, 300 kbps
RF ZigBee
Output Power +18 dBm Typical
Error Vector Magnitude % 5% Typical
Transmit Frequency 2.405 to 2.475 GHz
Communication Protocol ZigBee Protocol
Receive Sensitivity -104 dBm Typical
Standards
Compliance
FCC Title 47 CFR Part 15
Radiated and Conducted Emissions (incl. intentional
radiators)
IEC 61000 4-2,3,4,5,11,12 Electromagnetic Compatibility
ANSI C12.19 Compatible with Utility Industry End Device Tables
ANSI C12.20
National Standard for Electricity Meters - 0.2 and 0.5
Accuracy Classes
ANSI C12.21 Code for Electricity Metering
ANSI C37.90.1 (1989) Standard Surge Withstand Capability (SWC) Tests
Draft 10/7/2015