User Manual
Table Of Contents
Gridstream RF Enhanced Integrated FOCUS AX Quick Start Guide Landis+Gyr
8 98-1033 Rev AB Data Sheet
interference to radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Consult Landis+Gyr or an experienced radio technician for help
U WARNING: Changes or modifications to this device not expressly approved by Landis+Gyr
could void the user's authority to operate the equipment.
RF Exposure
In accordance with FCC requirements of human exposure to radio frequency fields, the radiating
element shall be installed such that a minimum separation distance of 20 centimeters will be
maintained.
Specifications
Category Specification Value or Range
Compatible
Meters
Landis+Gyr FOCUS Supported
Meter Forms
Form Class Voltage Units
1S&SD CL100 120 Vac
2S&SD CL200 240 Vac
2SE CL320 240 Vac
3S CL20 120 Vac
3S CL20 240 Vac
4S CL20 240 Vac
Only 1S and 2S are available with Service Disconnect
Gridstream
Radio General
RF Frequency Range 902.2 MHz Min, 927.9 MHz Max
RF Baud Rate 9.6 kbps Min, 115.2 kbps Max, Programmable
Output Power
25.25 kBm Min, 26.25 dBm Typ, 27.25 dBm Max. Over
temperature range, <2:1 VSWR load
Receive Sensitivity
-112 dBm Min, -102 dBm Max, At 10% PER, depends
on baud rate
Antenna Type Inverted F, Printed
Antenna Gain +3 dbi, Peak Gain