User's Manual
oÉëáÇÉåíá~ä=jÉíÉê=jçÇìäÉ=oÉíêçÑáí
RJQ `ÉääåÉí=d~ë=jçÇìäÉ=~åÇ=jÉíÉê=fåëí~ää~íáçå=dìáÇÉ
6AlignthemeterdrivedogwiththemodulewigglerandinstalltheMeter
Modulebasetothemeterbyscrewinginthetwocapturedstandoffscrews.
Thetorquerequirementforfasteningthescrewsis10inch‐pounds.For
modulesmanufacturedstartinginMay2005,forproperalignmentsee
Appendix A
,AligningtheNewAmericanMeterDriveDog.
Figure 5.5 American: Aligning the drive dog
Figure 5.6 American: Attaching the Meter Module onto the meter by screwing in two stand-off
fasteners
Check the wiggler on the meter module for free movement. Wiggler should turn at least 10
degrees but no greater than a 1/4 turn. If it is binding, then disassemble and realign. This is
also known as the “wiggle” test.
Improper alignment or tightening of the standoff screws may result in module or meter
failure.