User's Manual

`çããÉêÅá~ä=~åÇ=fåÇìëíêá~ä=jÉíÉê=jçÇìäÉ=fåëí~ää~ íáçå
`ÉääåÉí=d~ë=jçÇìäÉ=~åÇ=jÉíÉê=fåëí~ää~íáçå=dìáÇÉ SJNT
2Removethetampercapsandindexcoverfromtheoriginalmeter.Remove
thegasketifitisunserviceable.Cleantheworkareaswithawirebrushor
scraperasneeded.
Figure 6.28 Schlumberger/Actaris: Index cover removed
3OpenthepackagecontainingtheMeterModule,screws,andbattery.
4Openthebagcontaining thebattery.Carefullyremovethebattery.
5OpentheMeterModule,takingcaretoavoidpullingonthecables.
6 Connecttheprogrammingcablefromthehandheldcomputertothe
programmingportontheMeterModule.ProgramtheMeterModule.Ch
eck
thehandheldforsuccessfulprogramming.
7 ConnectthebatterytotheMeterModule.Assemblethebatteryintothe
retainingcliponthemetalbracket.
8Slidethemetalbracket(notthegreencircuitboard)intotheslotsofthe
clamshell(oneoftheclamshellhalveshasslotsonoppositesidesofthe
inte
rior).Ifyouarelookingdownintotheslots,thebatteryclipshouldbe
towardsthetop‐thelargecapacitorsonthecircuitboardgodeepintothe
clamshell.AssembletheMeterModulehalvestogetherwiththefoursmall
selftappingscrewsprovided.Thetorquerequirementis610inchpo
unds.
Ens
urethatthegasketisinplaceandthewiresarenotpinched.Installthe
tamperseals.
9Installthenewindexcover.Gentlyslidethecoverovertheindextoavoid
breakingthecounter. Becarefulnottodamagethedials.
Check condition of the index for looseness of index pointers on shaft, cracks on face
enamel, or peeling. Replace the index if dials are loose or if enamel is cracked or loose.