Installation Guide 98-1135 Rev AE 91
Figure 7 - 10. Cable to GPR Connection for a Single Form-A Volume Input
NOTE: Battery should not be connected until GPR is fully mounted.
Interface to Mil-Spec Circular Connector
For pulsers that have one or two Form-A outputs through a Mil-Spec circular connector, the
recommended cable for use is 19-2332. The installation procedure is as follows.
Table 7 - 2. Single Form-A Volume Input Definitions
GPR 19-2330 Cable Pulser Output Connector
GPR Sensor
Connector Pin #
Signal and Description Lead Color Terminal
Description
and Notes
1 N/C N/A N/A Not Applicable
2 N/C N/A N/A Not Applicable
3 N/C N/A N/A Not Applicable
4 N/C N/A N/A Not Applicable
5 Ground Drain Drain
Connection is
optional
6
CHAN B NO, Channel B
normally open
Orange Y Normally Open
7
CHAN B COM, Channel
B common
WHITE/ORANGE K Common
8 N/C N/A N/A Not Applicable
9
CHAN B TAMPER TEST,
channel B tamper test
WHITE/GREEN Y Tamper test
10 N/C N/A N/A Not Applicable
11 N/C N/A N/A Not Applicable