Landis+Gyr Chapter 6 - Index Cover Pulser Install and Operation Start Up
Installation Guide 98-1135 Rev AE 79
The connector on the cable is mated to the channel B on the GPR Sensor Connector as shown in the
figure below.
NOTE: Battery should not be connected until GPR is fully mounted.
Start the GPR Operation In Install Mode
By now, the GPR should be fully mounted without it's cover (Rockwell meter shown for reference):
Table 6 - 1. Single Form-C Volume Wiring Definitions
GPR Sensor Index Cover
GPR Sensor
Connector Pin #
Signal and Description Lead Color Terminal
Description
and notes
1 N/C N/A N/A Not Applicable
2 N/C N/A N/A Not Applicable
3 N/C N/A N/A Not Applicable
4 N/C N/A N/A Not Applicable
5 Ground Drain N/A Not Applicable
6
CHAN B NO, Channel B
normally open
Orange NO Normally Open
7
CHAN B COM, Channel
B common
WHITE/ORANGE COM Common
8 CHAN B NC Green NC Normally Closed
9
CHAN B TAMPER TEST,
channel B tamper test
WHITE/GREEN NO Tamper Test
10 N/C N/A N/A Not Applicable
11 N/C N/A N/A Not Applicable