User Manual

Table Of Contents
Landis+Gyr Chapter 5 - Sprague GPR Index Cover & GPR Install
Installation Guide 98-1135 Rev AE 75
Figure 5 - 32. GPR Facing Left Side of Meter
Figure 5 - 33. GPR Facing Right Side of Meter
3. Install the two screws and lock washers. Tighten the screws to 30 inch-pounds (+0 / -2 inch-
pounds).
A CAUTION: If the gas meter’s pipe route prevents installing the GPR as described in this
manual, the GPR may be mounted in a remote location away from the meter such as on a wall
or a gas pipe. The maximum cable length between the Index Cover Assembly and GPR must
not exceed 200 feet.
Remote GPR mounting is beyond the scope of this manual.
A CAUTION: In a Remote GPR Mounting environment, Pipe Bracket Kit 45-2478 may be used to
install the GPR on suitable plumbing pipes.