User Manual

Landis+Gyr Chapter 2 - GPR2-PT Mounting Instructions
Installation Guide 98-1678 Rev AA 21
Figure 2 - 20. Eagle Connections
Initial Configuration
To establish a communication between Corrector and GPR2-PT board, all wires should be connected
as described in the diagram. Eagle's Field Manager Tool is required to start communication with
Corrector from Laptop/PC. Specific MODBUS configuration required to initiate communication
between Corrector and GPR2-PT board.
Figure 2 - 21. Serial Cable Must Route Through GPR2-PT Strain Relief Slot
1. Install the GPR2-PT cover using the four security Torx screws included with the GPR2-PT. The
cover must be installed with the gasket tab inserted into the strain relief slot located at the bottom
left corner of the GPR2-PT enclosure as shown in the following photos.