Table of Contents Chapter 1: Pre-Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Safety Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 Pre-Installation Before You Begin This text contains the symbols which are explained below. A U NOTE: Notes provide important information about products and installation. CAUTION: Cautions provide information that you must read to avoid making relatively moderate errors. WARNING: Warnings provide special, must-read information. If you ignore a warning you may create a safety hazard, omit essential data, or make a critical error.
Chapter 1 - Pre-Installation Landis+Gyr understand that their supervisor’s responsibility does not relieve them from their individual responsibility to perform the work safely and to follow all safety rules and procedures applicable to their work. FCC Information to the User Manufacturer: Landis+Gyr Model Name: GPR2-PT FCC ID: R7PEC6R1S4 Module Model: GPR2-PT This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1.
Landis+Gyr U Chapter 1 - Pre-Installation WARNING: Substitution of components may impair the suitability for Class I, Division 2 applications. Replace battery only with Landis+Gyr part number 40-1235. Substitution of components may impair intrinsic safety. Please refer to the notes in Appendix B for connecting to this intrinsically safe device. Preliminary Checks 1. The installer will verify correct site, as specified on work order. 2.
2 GPR2-PT Mounting Instructions GPR2-PT Mounting The GPR2-PT module will be mounted vertically and upright, on a pipe-mounting bracket in proximity to the EVC, to minimize the cable length. This bracket can accommodate pipe diameters in the range of 1" to 3.25". Optionally, the GPR2-PT can be mounted on a nearby vertical surface. The cable will be routed in order to minimize its exposure to possible damage. Figure 1 below shows a typical installation. Figure 2 - 1.
Chapter 2 - GPR2-PT Mounting Instructions Landis+Gyr Figure 2 - 2. Enclosure Cable Entry Notch C. Using a T-10 security Torx driver, tighten the screws to 10 in-lbs (+/- 2 in-lbs). Tighten the screws using a crisscross pattern to secure the enclosure to the bracket. Figure 2 - 3.
Landis+Gyr Chapter 2 - GPR2-PT Mounting Instructions NOTE: The four longer security Torx screws are GPR2-PT enclosure cover screws. Cover screws are included in the 40-2424 GPR2-PT kit. 2. Secure the mounting bracket with GPR2-PT to the pipe. A. Hold the GPR2-PT bracket assembly against the pipe so that the GPR2-PT is vertical and upright. B. Insert V-bolt (28-1319) through the 2 middle holes in the bracket (28-0396). C. Add flat washers, then split-lock washers.
Chapter 2 - GPR2-PT Mounting Instructions Landis+Gyr Figure 2 - 5. GPR2-PT/Bracket Assembly for Vertical Pipe Installation 3. Route the serial cable along the most direct and convenient route between the Meter and the GPR2-PT (preferably along the pipe). Secure the serial cable to the pipe with black nylon UVrated tie wraps in locations along the pipe 12" apart. 4. Connect the cable to the EVC using the model-specific instructions below for Eagle or Mercury EVCs.
Landis+Gyr Chapter 2 - GPR2-PT Mounting Instructions GPR2-PT Mounting Instructions Eagle Cable Entry Connector Drain Screw Cable Port Figure 2 - 6. Eagle Corrector Wiring 1. Insert serial cable (19-2380) through cable port shown. If port is filled with a cap, replace with 16-1705 w/ 16-1706 or any similar, water-tight cord grip that will fit a 0.33 inch diameter cable. 2. Pull the cable through the port, far enough to reach the connector and drain hardware. 3.
Chapter 2 - GPR2-PT Mounting Instructions Landis+Gyr Serial Connection Wiring Diagram for Eagle Correctors Figure 2 - 7. XARTU Main Board Green Orange White/Orange 19-2380 Cable Figure 2 - 8. Serial Connection Wiring Diagram for XARTU Main Board 1. Once the serial leads and drain terminal are connected, close the EVC. Ensure that no cables are hanging between the door and the enclosure. 2. Installation is now complete.
Landis+Gyr Chapter 2 - GPR2-PT Mounting Instructions Mercury Cable Entry All Mercury EVC models will be retrofitted with the PT-board. This will provide the serial communication interface to the GPR2-PT. Although physically different, each model should have unused cable ports as shown in Figure 2 - 9 through Figure 2 - 11 below. Figure 2 - 9. Mercury ECAT Interior Figure 2 - 10.
Chapter 2 - GPR2-PT Mounting Instructions Landis+Gyr Figure 2 - 11. Mercury Mini-Max Interior 1. Insert serial cable (19-2380) through the appropriate cable port. If the port is filled with a cap, replace with 16-1704 or any similar, water-tight cord grip that will fit a 0.33 inch diameter cable (e.g. Mercury PN 20-8911). 2. Pull the cable through the port far enough to reach the connector and drain hardware. 3.
Landis+Gyr Chapter 2 - GPR2-PT Mounting Instructions Figure 2 - 13. Drain Locations in ECAT Serial Connection Wiring Diagram for Mercury/Honeywell Correctors Figure 2 - 14.
Chapter 2 - GPR2-PT Mounting Instructions Landis+Gyr RxD TxD GND White/Orange Orange Green 19-2380 Cable Figure 2 - 15. Serial Connection Wiring Diagram for PT Board 1. Once the serial leads and drain terminal are connected, close the EVC. Ensure that no cables are hanging between the door and the enclosure. 2. Installation is now complete. Battery Replacement Procedure 1. To change the battery of the GPR2-PT, first take off the cover by removing the 4 screws with a Torx T10 pin-head driver. 2.
Landis+Gyr Chapter 2 - GPR2-PT Mounting Instructions Corrector Connection Mercury Corrector (ERX) Figure 2 - 16. Mercury Connections Diagram for J5 Figure 2 - 17.
Chapter 2 - GPR2-PT Mounting Instructions Landis+Gyr Figure 2 - 18. Mercury Connections To establish a communication between Corrector and GPR2-PT board, all wires should be connected as described in the diagram from PT board. Mercury's Protocol Translator Configuration software is required to start communication with Corrector from Laptop/PC. Specific MODBUS configuration required to initiate communication between Corrector (PT board) and GPR2-PT board. Eagle Corrector (XARTU) Figure 2 - 19.
Landis+Gyr Chapter 2 - GPR2-PT Mounting Instructions Figure 2 - 20. Eagle Connections Initial Configuration To establish a communication between Corrector and GPR2-PT board, all wires should be connected as described in the diagram. Eagle's Field Manager Tool is required to start communication with Corrector from Laptop/PC. Specific MODBUS configuration required to initiate communication between Corrector and GPR2-PT board. Figure 2 - 21. Serial Cable Must Route Through GPR2-PT Strain Relief Slot 1.
Chapter 2 - GPR2-PT Mounting Instructions Landis+Gyr Figure 2 - 22. GPR2-PT Cover Gasket Tab and Cover Strain Relief Slot 2. Tighten the screws to 13 inch-pounds (± 1 inch-pound). Figure 2 - 23. GPR2-PT Cover Screws 3. Install tamper seals into the tamper cups that are part of the GPR2-PT cover. 4. Installation is now complete.
A GPR2-PT Waterproofing Applying Water Sealant to Circuit Board Connections CRC Di-Electric Grease Compound is recommended as a sealant to prevent water intrusion into the GPR2-PT Pulse Input and Battery circuit board connections. Figure A - 1. CRC Di-Electric Grease Compound NOTE: Novagard® G661 is also approved as an electrical sealant and is available in 5.3 ounce tubes.
Appendix A - GPR2-PT Waterproofing Landis+Gyr NOTE: CRC Di-Electric Grease Compound is electrical grade. 1. Liberally apply CRC Di-Electric Grease Compound (“the compound”) to the Battery and GPR2PT serial connectors as shown in Figure A - 2 and Figure A - 3. Figure A - 2. Apply the Compound to the Battery Connector Figure A - 3. Apply the Compound to the GPR2-PT Pulse Input Connector 2.
Landis+Gyr Appendix A - GPR2-PT Waterproofing 3. Liberally apply the compound to the connectors of the GPR2-PT serial and battery interface cables. Force the compound into ALL holes and cover ALL electrical contacts, as shown in the following photos. NOTE: The following photos show representative cables to illustrate compound application. Figure A - 5. Apply the Compound to GPR2-PT Cable Connectors: Cover All Contacts 4.
Appendix A - GPR2-PT Waterproofing Landis+Gyr Figure A - 6. The Compound Must Cover Wires and Connectors for Watertight Seal 6. Arrange the GPR2-PT serial and battery interface cables as shown in Figure A - 7. The cables must not interfere with or block the GPR2-PT antenna. A CAUTION: The GPR2-PT serial cable must be inserted into the GPR2-PT enclosure strain relief slot as shown. NOTE: Battery should not be connected until GPR2-PT is fully mounted. 7.
Landis+Gyr Appendix A - GPR2-PT Waterproofing Figure A - 8.
Appendix A - GPR2-PT Waterproofing Landis+Gyr Ordering Information CRC Di-Electric Grease Compound Model: 02085 Description: Di-Electric Grease, Silicone, Net 3.3 oz. Manufacturer: CRC Industries Americas Group 885 Louis Drive Warminster, PA 18974-2869 Phone: (215) 674-4300 Email: info@crcindustries.com Website: http://www.crcindustries.com/ Novagard® G661 may be ordered from: Novagard Solutions® 5109 Hamilton Avenue Cleveland, OH 44114 Phone: (216) 881-3890 Facsimile: (216) 881-6977 www.Novagard.
Landis+Gyr Appendix A - GPR2-PT Waterproofing 3M Distributors http://3mcollision.com/dealers/search?zip=30022&lat=34.029613&lng=- 84.23841700000003 DKHardware.com Phone: 877-509-8040 CRL Screw-On Uncut Standard Urethane Nozzle Item # UN0Z http://www.dkhardware.com/product-11007-un0z-screw-on-uncut-standard-urethane- nozzle.html Ellsworth Adhesives W129 N10825 Washington Dr. Germantown, WI 53022 Phone: 1-877-454-9224 Website: http://www.ellsworth.com/Home.
B Installation in Hazardous Locations Information The following information describes and limits what can be attached to the GPR2-PT in a Division 1 location per the UL certification. 1. GPR2-PT Entity Parameters: • Uo (Voc) = 6.3 V dc • Io (Isc) = 7.34 A • Po = 5.91 W • Co (Ca) = 207 uF • Lo (La) = 43 uH 2. The output current of the GPR2-PT is limited by a resistor such that the output voltage-current plot is a straight line drawn between open-circuit voltage and short-circuit current. 3.
Appendix B - Installation in Hazardous Locations Landis+Gyr 6. Where multiples circuits extend from the GPR2-PT, they must be installed in separate cables or in one cable having suitable installation. Refer to Article 504.30(B) of the National Electrical Code (ANSI/NFPA 70) and Instrument Society of American Recommended Practice ISA RP12.6 for installing intrinsically safe equipment. 7. Intrinsically safe circuit must be wired and separated in accordance with Article 504.