The table below describes the fields on the Command Scheduler tab.
Table 3 - 9. Command Scheduler Tab
Field Description
Event Mask: over 100 choices are available for notification scheduling. Choices for event masking include:
Disabled, Log Only, Advisory, and Alarm.
Erase Control
EraseZero
Always the best choice for this screen. This option makes no changes to
existing parameters.
EraseAll
Never to be used unless a start-from-zero meter commissioning action is in-
process.
EraseCommands
Clears commands that have been entered into the Command section of the
Command Scheduler tab.
Command Schedule
<Command Type>
Cached Reads /
Passthru PDU command /
Interval Data Pump /
Snap Read Pump /
Advisory Events /
Init Push Message /
Meter Events /
Radio Virtual Memory Read
(Short) /
WAN Node Information
Read /
Predefined Memory Read
Command chosen by the user for implementation and notification.
Start Time
Displays the user-selected date and time for launching the specified
command.
<Period Type>
Run Minute based /
Run Day based
User-programmed test parameter types for command launch intervals.
<Test Interval Setting>
Cached Read /
Run Randomized /
Normal
User-programmed test parameter intervals for command launch.
Period display The user-defined data field that displays the test interval.
Accept / Cancel
Clicking this button sets the changed parameter for the command being
configured or cancels the change.
<Buttons>
Get Scheduled Commands Polls the meter to refresh the scheduled commands.
Display Scheduled
Commands Report
Displays a report of the scheduled commands.
Set Scheduled Commands
Loads all new commands into the meter. The user MUST click Get
Scheduled Commands to verify that the new commands have loaded.
Confirmation does not appear in the Activity Log.