Chapter 3 - Using Endpoint Testing Manager (ETM) Landis+Gyr
60 98-1671 Rev AA User Guide
Figure 3 - 28. Firmware Download Tab Connected to an Endpoint with v6.x Firmware
Battery End Point Firmware Download
No meter specifics will be displayed on this tab when ETM is connected to a battery end point.
Module version will be displayed, and firmware unique to the connected (battery end point) module
will be found on the drop-down menu.
Select the firmware for download by highlighting and click the Start Download button to launch the
event.
Module Tab
NOTE: Due to the differences in meter setup with integrated Focus AX meters, only the Module
Firmware option appears on the Module tab when ETM connects to an integrated Focus AX meter.
Metrology firmware upgrades occur automatically within the build; other fields on this screen are
not necessary for endpoint configuration.
The Module tab is comprised of the DCW Information, Timing, Current Time, Set Time, and
Command fields. The fields on this tab are only enabled if a meter has been run with a status of
Passed.
The table below describes the fields on the Module tab.
Table 3 - 7. Module Tab
Field Description
DCW Information
Get DCW Information
<button>
Provides the most current DCW information of the endpoint tested.
Install DCW <button>
Allows you to load a DCW on the endpoint tested.
The DCW available for download will be limited to the latest specified DCW
for the firmware version on the meter.
Timing
Module Time (GMT) Displays the current module time.
Meter Time (GMT) Displays the current meter time.
Get Time Delta <button>
Generates a report that displays the difference between the module time and
the meter time. Closing the report enables the Sync Meter and Module button